Skip to main content
. 2014 Mar 19;14:110. doi: 10.1186/1471-2393-14-110

Table 4.

Effect of position (physician vs. nurse) on the degree of accuracy of blood loss estimation for the research three phases

 
Phase 1
Phase 2
Phase 3
  Physician MD (sd) Nurse MD (sd) P-value Physician MD (sd) Nurse MD (sd) P-value Physician MD (sd) Nurse MD (sd) P-value
Station 1 (200 ml)
-35.2 (96.1)
-49.8 (91.5)
0.46
40.0 (119.4)
16.5 (78.3)
0.22
28.3 (84.0)
40.5 (129.1)
0.63
Station 2 (225 ml)
-4.7 (141.8)
-8.4 (131.3)
0.89
94.3 (143.8)
48.9 (105.0)
0.07
103.4 (149.2)
33.1 (76.5)
0.001
Station 3 (250 ml)
-64.8 (141.6)
-85.0 (102.2)
0.40
48.4 (117.6)
11.7 (89.6)
0.08
84.5 (158.3)
10.4 (103.8)
0.004
Station 4 (500 ml)
75.2 (447.7)
-172.4 (190.2)
<0.0001
20.9 (194.6)
-61.1 (337.3)
0.22
39.1 (195.1)
-80.5 (197.8)
0.005
Station 5 (550 ml)
-215.3 (175.7)
-197.7 (251.8)
0.73
7.8 (198.1)
-59.4 (175.8 )
0.08
61.4 (229.9)
-42.1 (163.5)
0.008
Station 6 (550 ml)
-157.6 (247.2)
-192.3 (258.7)
0.53
-44.0 (261.3)
-70.7 (231.1)
0.60
-5.2 (193.1)
-48.1 (210.1)
0.33
Station7 (700 ml)
-238.6 (240.1)
-234.9 (245.0)
0.94
-56.2 (215.9)
-57.9 (243.0)
0.97
-57.4 (211.8)
-1.9 (204.2)
0.21
Station 8 (900 ml)
-243.9 (366.4)
-337.3 (300.4)
0.17
119.0 (445.1)
-89.8 (371.6)
0.01
96.7 (440.9)
-67.6 (325.9)
0.03
Station 9 (1050 ml)
-444.1 (340.2)
-434.0 (550.9)
0.93
-15.7 (350.5)
-169.8 (347.0)
0.04
-65.5 (265.2)
-112.5 (365.3)
0.52
Station 10 (2000 ml) -648.3 (785.0) -871.7 (648.6) 0.13 -8.6 (649.7) -290.1 (865.5) 0.11 45.8 (616.1) -246.9 (630.2) 0.03

MD = Mean Difference.

sd = Standard deviation.

Stations were ordered in an ascending order of simulated blood loss volumes, although the sequence was random for the different phases conduction.