Table 4.
Recommendation | 2013 Level |
---|---|
Reporting of Appropriate Use Criteria Categories of Appropriate, May Be Appropriate (Uncertain), and Rarely Appropriate (Inappropriate) | Required |
Dosimetry Reporting | Required |
Development of DRLs for a variety of specific cardiac imaging tasks | Required |
Implementation of Continuous Quality Improvement Programs | Required |
Implementation of Decision Support Tools | Recommended |
Continuing Medical Education For Referring Physicians | Recommended |
Creation of a Repository from Electronic Health Record Data on Each Patient's Past History of Medical Imaging Radiation Exposure | Suggested |
Definitions:
Required: Majority opinion that standardized laboratory practice of this recommendation is consistent with effective, patient-centered imaging.
Recommended: General agreement that standardized laboratory practice of this recommendation would enhance patient-centered imaging.
Suggested: Expert opinion that standardized laboratory practice of this recommendation would enhance patient-centered imaging.