Table 2. Analytical sensitivity of the egl LAMP assay.

Concentration (cells/mL) GBBC 1172 (Phylotype I) RUN 30 (Phylotype IIA) GBBC 729 (Phylotype IIB) LMG 2296 (Phylotype III) RUN 71 (Phylotype IV)
tp (min) tp (min) tp (min) tp (min) tp (min)
108 12.7 ±0.38 15.8 ±1.59 12.9 ±1.07 12.2 ±0.06 19.4 ±1.67
107 14.2 ±1.81 16.5 ±2.73 14.7 ±1.76 13.8 ±1.56 18.8 ±1.90
106 17.0 ±3.03 18.1 ±3.97 16.3 ±1.86 15.7 ±2.03 19.3 ±2.44
105 18.1 ±3.13 23.3a 17.7 ±2.41b 17.4 ±2.02 21.3a
104 20.8 ±3.99 26.3a 21.3a 20.5 ±2.28 -
103 - - - - -
102 - - - - -
Tm 94.1 ±0.10 93.5 ±0.27 93.2 ±0.08 94.1 ±0.14 93.8 ±0.25

Data are means (±SD), calculated from three independent runs.

“-”: negative result (absence of signal).

a

, detected once out of three replicates.

b

, detected twice out of three replicates.

Data obtained on different R. solanacearum phylotypes samples, from boiled bacterial suspensions.