TABLE II.

Mean and Standard Deviation of the PSNR (dB) for 18 SDOCT Foveal Images (With 50% Data Missing) Reconstructed by CS-Recovery [62] With Random Sampling Pattern, CS-Recovery [62] With Regular Sampling Pattern, Bicubic, Tikhonov [63], BM3D [64]+Bicubic, ScSR [32], 2-D-SBSDI-Nomap, 2-D-SBSDI, and SBSDI Methods With Regular Sampling Pattern.

CS-recovery [62] - Random* CS-recovery [62] - Regular* Bicubic -Regular* Tikhonov [63] -Regular* BM3D [64] +Bicubic -Regular* ScSR [32]-Regular* 2-D-SBSDI-nomap Regular* 2-D-SBSDI-Regular* SBSDI -Regular
Mean 20.36 19.86 18.68 23.30 27.12 24.26 25.94 27.63 28.32
Standard deviation 0.65 0.58 0.98 1.76 2.49 1.32 1.80 2.34 2.57
P value (PSNR) 0.0002 0.0002 0.0002 0.0002 0.0002 0.0002 0.0002 0.0003
*

PSNR: p < 0.05.

Best Results in the Mean Values are Labeled in Bold