TABLE IV.

Mean and Standard Deviation of the PSNR (dB) for 18 SDOCT Foveal Images (With 75% Data Missing) Reconstructed by CS-Recovery [62] With Random Sampling Pattern, CS-Recovery [62] With Regular Sampling Pattern, Bicubic, Tikhonov [63], BM3D [64]+Bicubic, SCSR [32], 2-D-SBSDI-Nomap, 2-D-SBSDI, and SBSDI Methods With Regular Sampling Pattern.

CS-recovery [62] - Random* CS-recovery [62] - Regular* Bicubic -Regular* Tikhonov [63] - Regular* BM3D [64] +Bicubic - Regular* ScSR [32]-Regular* 2-D-SBSDI-nomap Regular* 2-D-SBSDI-Regular* SBSDI -Regular
Mean 21.78 21.65 18.52 22.52 27.26 25.76 26.95 27.64 28.30
Standard deviation 0.77 0.75 0.49 0.95 2.50 1.63 2.04 2.31 2.54
P value (PSNR) 0.0002 0.0002 0.0002 0.0002 0.0002 0.0002 0.0002 0.0003
*

PSNR: p < 0.05.

Best Results in the Mean Values are Labeled in Bold