Skip to main content
. 2014 Apr 21;13:46. doi: 10.1186/1475-925X-13-46

Table 1.

Spectral analysis of instantaneous pulse rate variability (iPRV) during different physiologic challenges

  LF (ms2) HF (ms2) VHF (ms2)
Baseline
1161+/−1841
2223+/−2563
1258+/−1244
6-cycle
8522+/−5865§
1468+/−1424
2080+/−2395
30-cycle
897+/−822
898+/−1021
2333+/−2346§
HUT 802+/−624 1196+/−1397* 939+/−671

Present form is mean +/− SD with n = 15; *means p < 0.05 compared with baseline; §means p < 0.01 compared with baseline.

LF denotes low frequency band (0.04-0.15 Hz); HF denotes high frequency band (0.15-0.4 Hz); VHF denotes very high frequency band (0.4-0.9 Hz); 6-cycle denotes paced respiration with 6 cycles per minute; 30-cycle denotes paced respiration with 30 cycles per minute; HUT denotes head-up tilt.