Table 1. Sonication parameters of the four experimental groups.
Group 1 | Group 2 | Group 3 | Group 4 | |
Number of rats | 34 | 34 | 30 | 30 |
Acoustic pressure (MPa) | 0.5–4.5 | 0.5–4.5 | 0.1–1.5 | 0.1–1.5 |
Pulse repetition frequency (Hz) | 10 | 10 | 10 | 10 |
Number of cycles | 10000 | 10000 | 10000 | 10000 |
Duration of sonication (s) | 60 | 60 | 60 | 60 |
Number of MRI evaluations | 18 | 18 | 18 | 18 |
Number of H&E staining evaluations | 18 | 18 | 18 | 18 |
Number of TUNEL staining evaluations | 18 | 18 | 18 | 18 |
Number of EB staining evaluations | 34 | 34 | 30 | 30 |
Group 1 = in-house submicron bubbles with 10-MHz FUS sonication; Group 2 = SonoVue with 10-MHz FUS sonication; Group 3 = in-house submicron bubbles with 1-MHz FUS sonication; Group 4 = SonoVue with 1-MHz FUS sonication.