Table 3.

Parameter estimates from MLR model using information from FLT only (absolute values and changes).

Multiple Linear Regression Model for Predicting Overall Survival (MLR-1)
Predictor Variable Parameter Estimates P-value
FLT Vd absolute value at S2 −443.29 <.0001
FLT k4 ratio (S2/S1) +158.44 <.0001
FLT k2 ratio (S3/S2) +289.66 <.0001
Intercept +87.95 0.22
*

R2 = 0.85, adjusted-R2 = 0.82, root MSE = 106 days, and the average variance inflation factors were 1.0.

S1 = Baseline FLT PET, S2 = FLT PET at 2 weeks after start of treatment, S3 = FLT PET at 6 weeks after start of treatment.