Table 3.

Dosimetry studies on IMRT procedures. The last column describes the type of dose data that was presented in each study. ORS stands for occupational radiation safety studies.

Author Dosimetry method Secondary radiation Accelerator Quantity
IMRT
Followill et al (1997) Measurement Neutron and photon GE Saturne 43 Whole-body dose equivalent
Mutic and Klein (1999) Measurement Photon Varian Clinac 2300C/D Out-of-field dose
Stern et al (1999) Measurement Photon Clinac 2100C
6 MV Clinac 600C
Out-of-field dose
Verellen and Vanhavere (1999) Measurement Photon Siemens (KDS 2) Mevatron Whole-body dose equivalent
Ongaro et al (2000) Monte Carlo (MCNP-GN) Neutron Elekta SL20
Siemens Mevatron
Out-of-field dose
Lin et al (2001) Measurement Neutron Siemens Primus ORS
Mutic et al (2002) Measurement Photon Elekta Precise Out-of-field dose
Followill et al (2003) Measurement Neutron Varian Clinac 2100C, 2300C, 2500
Siemens Primus, KD, MD, MD2
Elekta SL20, SL25 GE Saturne 43
Q-value
Difilippo et al (2003) Monte Carlo (MCNPX) Neutron, proton and alpha a In-field dose Organ dose
Chibani and Ma (2003) Monte Carlo (MCNPX) Neutron, proton and alpha Varian Clinac 2160C
Siemens Primus
In-field dose
Out-of-field dose
Vanhavere et al (2004) Measurement Neutron and photon Varian Clinac 2300C/D Organ equivalent dose
Zanini et al (2004) Monte Carlo (MCNP-GN) Neutron Varian Clinac 2300C/D Out-of-field dose
Koshy et al (2004) Measurement Photon a Organ equivalent dose
Barquero et al (2005) Monte Carlo (MCNPX) Neutron b Organ equivalent dose
Pena et al (2005) Monte Carlo (MCNPX) Neutron Siemens Primus ORS
Kry et al (2005a, 2005b) Measurement Neutron and photon Varian Clinac 2100C
Siemens Primus
Out-of-field dose organ equivalent dose
Whole-body dose equivalent
Howell et al (2005) Measurement Neutron Varian 2300C/D Out-of-field dose
Howell et al (2006) Measurement Neutron and photon Varian Trilogy Clinac, 23EX Organ equivalent dose
Klein et al (2006) Measurement Photon Varian Clinac 23EX Out-of-field dose
Mazonakis et al (2006) Monte Carlo (MCNP) Photon Philips SL75/5 Out-of-field dose
Reft et al (2006) Measurement Neutron and photon Siemens Primus
Philips SL-C
Varian Clinac 2100
Out-of-field dose
Sharma et al (2006a, 2006b) Measurement Photon Varian Clinac 2100 C/D Out-of-field dose
Wang and Xu (2007) Measurement Photon Varian Clinac 21EX
Kry et al (2006) Monte Carlo (MCNPX) Photon Varian Clinac 2100C Out-of-field dose
Kry et al (2007b) Monte Carlo (MCNPX) Neutron and photon Varian Clinac 2100C Out-of-field dose
Mansur et al (2007) Measurement Photon a Organ equivalent dose
Tomotherapy
Mutic and Low (1998) Measurement Photon Peacock/MIMIC tomotherapy
Varian Clinac 6/100
Out-of-field dose
Robinson et al (2000) Generic model Photon a ORS
Meeks et al (2002) Measurement Photon Clinac 18/R – CORVUS
TPS
Out-of-field dose
Jeraj et al (2004) Monte Carlo (MCNP) Photon TomoTherapy Hi-Art II
Balog et al (2005) Measurement Photon TomoTherapy Hi-Art II ORS
Ramsey et al (2006) Measurement Photon TomoTherapy Hi-Art
Varian Clinac 21EX
Out-of-field dose
Stereotactic radiotherapy
Shepherd et al (1997) Measurement Photon Philips SL75/5
Ioffe et al (2002) measurement Photon 60Co Leksell Gamma Knife Out-of-field dose
Maarouf et al (2005) Measurement Photon Elekta SL 75/20 Out-of-field dose
Petti et al (2006) Measurement Photon CyberKnife Radiosurgery System Out-of-field dose
Hasanzadeh et al (2006) Measurement Photon 60Co Leksell Gamma Knife Organ equivalent dose
a

Unable to obtain machine type.

b

Model of neutron source used.