Skip to main content
. 2013 Dec 13;271(6):1815–1822. doi: 10.1007/s00405-013-2849-6

Table 3.

The average hearing level (dBHL) in pure tone audiometry

Average hearing level (dBHL) Frequency (Hz)
125 250 500 1,000 2,000 3,000 4,000 6,000 8,000
Group one (n = 119 ears)
 Before e.s. 25.6 27 26.4 31.4 35.2 41.1 47.6 56.4 51.6
 Directly after e.s. 29.4 28.5 27.5 27.2 30.1 36.5 42.0 53.4 49.6
 90 days after e.s. 30.3 29.1 27.3 28.3 31.0 36.9 42.5 53.3 49.4
Group two (n = 65 ears)
 Before placebo e.s 30.9 31.4 31.7 33.2 35 39.1 42.0 50.0 49.4
 Directly after placebo e.s. 27.9 29.1 31.1 31.5 33.2 35.3 41.5 47.0 45.3
 90 days after placebo e.s. 25.6 25.6 27.8 33.3 36.1 35.0 39.5 47.8 47.8

e.s. electrical stimulation