. 2012 Jan 4;23(1):56–64. doi: 10.1089/hgtb.2011.217

FIG. 3.

FIG. 3.

IEX particle assay. (a) Seventy-five microliters of an empty particle AAV8 preparation (lot no. Z4033) was loaded onto a 0.34-ml CIM-QA disk, using FPLC, and eluted with a 50–150 mM salt gradient. The y axis shows the absorbance (mAU) at 280 nm and the x axis the elution volume (ml). The detected conductivity and absorbance are represented by solid light and dark blue lines, respectively. The vertical dashed pink line represents the point of vector injection. (b) A full AAV8 vector preparation (lot no. V0083, 1×1012 GC) was run under the same binding/elution conditions as used for the empty particle preparation. Fractions were quantified for vector GC content and those fractions containing >99% of the loaded material are indicated (shaded box). (c) An overlay of the elution profiles of the empty and full AAV8 vector preparations is shown.