Skip to main content
. 2014 Jan 13;23(10):1074–1083. doi: 10.1089/scd.2013.0625

Table 3.

Test Results of Interfering Factors

    Endotoxin dilution (EU/mL)        
Studied cultures (phase MCB) Solutions 0.06 0.03 0.015 0.0075 Endpoint (EU/mL) Log10 endpoint Mean Antilog10
1 B + + 0.03 −1.52 −1.37 0.04
    + + 0.03 −1.52    
    + 0.06 −1.22    
    + 0.06 −1.22    
  C + + 0.03 −1.52 −1.37 0.04
    + 0.06 −1.22    
2 B + + 0.03 −1.52 −1.29 0.05
    + 0.06 −1.22    
    + 0.06 −1.22    
    + 0.06 −1.22    
  C + + 0.03 −1.52 −1.52 0.03
    + + 0.03 −1.52    
3 B + + 0.03 −1.52 −1.29 0.05
    + 0.06 −1.22    
    + 0.06 −1.22    
    + 0.06 −1.22    
  C + + 0.03 −1.52 −1.37 0.04
    + 0.06 −1.22    

Solution A, solution of the preparation being examined that is free of detectable endotoxins; solution B, test for interference; solution C, control of the labeled lysate sensitivity; solution D, negative control (water for bacterial endotoxin test).