Table 2.
B | CSD | |||||
---|---|---|---|---|---|---|
Parameter | r | R2 | p | r | R2 | p |
Dynamic Modulus (MPa) | (0.94, 0.96) | (0.88, 0.92) | <0.001 | (−0.56, −0.62) | (0.31, 0.39) | <0.001 |
Damage (mm/mm) | (−0.35, −0.49) | (0.12, 0.24) | (NS, 0.009) | (0.08, 0.29) | (0.00, 0.08) | NS |
Tangent Stiffness (N/mm) | (0.46, 0.65) | (0.21, 0.42) | (0.004, <0.001) | (−0.24, −0.43) | (0.05, 0.18) | (NS, 0.007) |
Peak Strain (mm/mm) | (−0.40, −0.49) | (0.16, 0.24) | (0.013, 0.003) | (0.05, 0.28) | (0.00, 0.08) | NS |
Hysteresis MPa*mm/mm) | (0.43, 0.69) | (0.18, 0.47) | (0.007, <0.001) | (−0.27, −0.52) | (0.07, 0.27) | (NS, <0.001) |
Cycles to Failure | (0.21, 0.30) | (0.05, 0.09) | NS | (−0.08, 0.17) | (0.00, 0.03) | NS |
For each load, data are shown as ranges (min, max) between 5 and 95% of tendon fatigue life and all loads. Parameters with non-significant coefficients of determination are indicated as “NS.”