TABLE 2.
Performances | Diode limiter | Commercial limiter | BPT-based limiter | |
---|---|---|---|---|
IL (dB) | 20 MHz | –6.0 | –6.6 | –6.3 |
60 MHz | –6.8 | –7.7 | –7.4 | |
100 MHz | –8.0 | –8.0 | –7.7 | |
THD (dB) | 20 MHz | –72.4 | –74.1 | –77.3 |
60 MHz | –59.9 | –59.9 | –64.9 | |
100 MHz | –69.5 | –66.3 | –74.6 | |
TNF (dB) | 20 MHz | 11 | 10.4 | 9.6 |
60 MHz | 10.7 | 10.3 | 8.2 | |
100 MHz | 10.4 | 10.7 | 6.6 | |
Bandwidth (MHz) | 131 | 147 | 135 | |
RT (ns) | 89 | 82 | 43 |
* The IL, THD, and TNF values were measured at 50 mVp-p. RT is the time caused by negative pulse.