Skip to main content
. 2013 Jul 11;3(3):126–135. doi: 10.3390/membranes3030126

Table 3.

Determination of the critical and threshold flux for the nanofiltration (NF) membrane.

TMP (bar) t (h) (−∆ m/∆t)° (L h−2 m−2 bar) × 10−5 (−∆ m/∆t)* (L h−2 m−2 bar) × 10−5
2 1 14.124 14.124
3 2 5.817 14.124
4 3 6.394 14.124
5 4 12.191 14.124
6 5 16.130 14.124
7 6 16.847 14.124