Water uptake (WU), ionic exchange capacity (IEC), and parameters derived from the thermal analysis for the five prepared membranes.

Code Filler (5 wt %) IEC mequiv g−1 WU ΔH/J g−1 (DSC) Ttr/°C (DSC)
N none 0.880 37% 76.9 185
N-E400 E400 0.834 38% 105 163
N-E400S E400S 0.812 37% 93.3 153
N-F110 F110 0.827 40% 114 146
N-F110S F110S 0.820 40% 181 153