Table 2.

Agreement (mean ±1 s.d.) between measured and model-predicted tibiofemoral joint contact forces over five trials of normal walking

Medial Lateral Total
R 2, Pearson's 0.87 (0.03) 0.07 (0.08) 0.68 (0.08)
R 2, Coefficient of determination 0.81 (0.05) −1.29 (0.92) 0.60 (0.09)
Bias (BW) 0.09 (0.02) 0.06 (0.08) 0.15 (0.09)
Precision (BW) 0.24 (0.03) 0.42 (0.08) 0.48 (0.08)
RMS error (BW) 0.26 (0.03) 0.42 (0.08) 0.51 (0.07)
Peak 1 (BW) Predicted 1.95 (0.08) 0.81 (0.31) 2.76 (0.32)
Measured 1.73 (0.09) 0.65 (0.06) 2.37 (0.12)
Error 0.22 (0.10) 0.17 (0.34) 0.39 (0.34)
Peak 2 (BW) Predicted 1.60 (0.17) 1.11 (0.13) 2.71 (0.17)
Measured 1.56 (0.14) 1.05 (0.06) 2.60 (0.10
Error 0.04 (0.23) 0.06 (0.14) 0.11 (0.20)