Skip to main content
. Author manuscript; available in PMC: 2014 May 20.
Published in final edited form as: J Chromatogr B Analyt Technol Biomed Life Sci. 2012 Sep 15;907:117–125. doi: 10.1016/j.jchromb.2012.09.018

Table 4.

Autosampler stability (n = 5), bench-top stability (n = 3) and freeze-thaw stability (n = 3) of COT, NCOT, OHCOT and COTNO at 3.0 and 75.0 ng/mL concentrations in plasma and brain homogenate. Stabilities are shown in forms of percentage of relative concentration to time zero control (mean ± SD).

Matrix Analyte Conc. (ng/mL) Autosampler Stability (%) Bench-top Stability (%) Freeze-Thaw Stability (%)

Plasma COT 3.0 92.36±4.57 97.43±8.31 104.10±4.59
75.0 98.08±3.28 100.15±4.88 102.29±1.63

NCOT 3.0 98.65±3.63 102.65±5.47 99.56±2.55
75.0 96.94±3.03 99.76±3.57 102.49±5.04

OHCOT 3.0 100.20±2.39 100.82±3.47 97.26±1.79
75.0 101.39±1.75 99.28±4.76 102.46±0.88

COTNO 3.0 99.87±4.88 105.72±5.02 98.32±1.15
75.0 100.54±3.19 101.17±4.75 100.31±1.58

Brain COT 3.0 101.60±1.80 95.26±3.94 95.61±10.62
75.0 96.95±2.38 102.39±6.13 101.88±2.98

NCOT 3.0 101.53±3.28 100.49±3.65 97.09±9.24
75.0 98.93±2.69 100.64±4.54 97.88±0.29

OHCOT 3.0 101.74±3.81 100.78±5.88 93.70±7.34
75.0 101.33±3.12 101.48±3.08 99.14±2.35

COTNO 3.0 99.44±3.73 99.68±4.99 103.13±6.72
75.0 98.27±2.89 106.59±3.08 95.69±2.89