Table 2.
Controls | SCIBac | SCINo-Bac | p-values | |
---|---|---|---|---|
AMT (% MSO) | 38.3 ± 6.9 | 56.1 ± 14.0 | 59.2 ± 14.7 | p < 0.001 |
Stimulation intensity (% MSO) | ||||
110% AMT | 41.9 ± 7.8 | 61.5 ± 15.4 | 64.6 ± 16.4 | p < 0.001 |
120% AMT | 46.1 ± 7.7 | 67.5 ± 17.0 | 70.3 ± 18.0 | p < 0.001 |
150% AMT | 57.7 ± 9.0 | 78.9 ± 16.4 | 82.4 ± 17.0 | p < 0.001 |
MEP size (mV) | ||||
Index finger abduction | ||||
110% AMT | 1.5 ± 1.1 | 1.2 ± 0.7 | 0.92 ± 0.4 | p = 0.30 |
120% AMT | 3.4 ± 2.2 | 2.2 ± 1.9 | 1.4 ± 0.9 | p = 0.045 |
150% AMT | 7.4 ± 3.3 | 3.0 ± 2.4 | 2.3 ± 1.5 | p < 0.001 |
p-values | p < 0.001 | p = 0.002 | p = 0.001 | |
Precision grip | ||||
110% AMT | 1.2 ± 0.9 | 1.0 ± 0.6 | 0.90 ± 0.4 | p = 0.67 |
120% AMT | 2.7 ± 1.7 | 1.8 ± 1.6 | 1.3 ± 0.9 | p = 0.11 |
150% AMT | 6.0 ± 2.6 | 2.5 ± 2.1 | 2.2 ± 1.5 | p < 0.001 |
p-values | p < 0.001 | p = 0.003 | p = 0.001 |