Skip to main content
. 2014 May 8;9:109. doi: 10.1186/1748-717X-9-109

Table 5.

The absorbed dose per 1 Gy of therapeutic dose at each organ

Organ Modality\ID Organ dose per 1 Gy (cGy/Gy)
1 2 3 4 5
Thyroid
IMRT
0.4
0.1
0.6
1.1
0.3
VMAT
0.3
0.1
0.5
0.9
0.3
TOMO
0.4
0.2
0.4
0.8
0.2
Lung
IMRT
2.6
1.1
5.2
8.8
1.8
VMAT
2.8
0.1
5.5
10.1
2.4
TOMO
6.9
3.0
11.6
16.5
6.1
Stomach
IMRT
10.5
30.7
49.3
26.0
1.7
VMAT
23.4
30.5
49.5
30.3
7.3
TOMO
28.3
46.7
53.3
43.0
13.5
Normal liver
IMRT
41.0
20.1
45.2
45.7
29.3
VMAT
42.7
18.5
38.7
54.1
30.6
TOMO
47.0
25.3
44.9
49.8
35.0
Small intestine
IMRT
1.3
0.4
1.9
4.8
0.7
VMAT
1.3
0.5
1.9
4.8
1.1
TOMO
1.4
0.3
1.9
15.7
0.6
Prostate/Ovary
IMRT
0.5
0.2
0.5
1.2
0.3
VMAT
0.4
0.1
0.5
1.0
0.3
TOMO
0.4
0.1
0.5
0.9
0.2
Rectum IMRT
0.3
0.1
0.4
0.9
0.2
VMAT
0.3
0.1
0.4
0.7
0.2
TOMO 0.3 0.1 0.3 0.7 0.2

The in-field region organs were the lung, stomach, and normal liver. The other organs were out-of-field. The doses of in-field region organs were calculated from the dose-volume histogram, and the doses of out-of-field region organs were measured by RPLGD detectors inside a humanoid phantom.