Skip to main content
. 2014 May 15;8:303. doi: 10.3389/fnhum.2014.00303

Table 2.

(A) Coherences that differed between breath counting (BC) and resting (R) at p(corrected) < 0.05. Intracortical lagged coherences (top), and head-surface conventional coherences (bottom). (B) Head surface coherences between electrode sites corresponding to the ROIs in a (top), and intracortical lagged coherences between ROIs corresponding to the electrode sites in a (bottom).

(A) Sites at p (cmt) < 0.05 (B) Corresponding sites
Intracortical lagged coherence Corresponding head-surface coherence
From To Coherence From To Coherence
Hz-Band BA BA BC R BC-R t p p (cmt) Electrode BC R BC-R t p
T 10 L 40 R 0.154 0.191 –0.037 –3.91 0.001 0.04 Fp1 L P4 R 0.611 0.601 0.010 2.10 0.05
T 10 R 17 R 0.163 0.191 –0.027 –4.18 0.0004 0.02 Fp2 R O2 R 0.564 0.560 0.004 0.76 0.5
A2 10 R 10 R 0.193 0.227 –0.034 –4.32 0.0003 0.01 Fp2 R F4 R 0.748 0.748 0.000 0.14 0.9
B3 10 L 3 R 0.071 0.084 –0.013 –4.26 0.0003 0.02 F3 L C4 R 0.207 0.212 –0.005 –0.79 0.4
Head-surface conventional coherence Corresponding intracortical lagged coherence
From To Coherence From To Coherence
Hz-Band Electrode BC R BC-R t p p (cmt) BA BA BC R BC-R t p
B2 F8 R O2 R 0.390 0.364 0.026 4.21 0.0004 0.03 47 R 17 R 0.137 0.144 –0.007 –0.99 0.3
B3 F3 L Fz M 0.607 0.592 0.015 4.26 0.0003 0.02 10 L 8 M 0.105 0.095 0.010 1.33 0.2
B3 Fz M P4 R 0.441 0.425 0.016 3.91 0.001 0.04 8 M 40 R 0.084 0.089 –0.006 –2.46 0.02
G F7 L Fz M 0.285 0.247 0.038 3.57 0.002 0.05 47 L 8 M 0.071 0.077 –0.007 –1.20 0.2