Skip to main content
. 2014 May 21;5:76. doi: 10.3389/fneur.2014.00076

Table 4.

Comparison of the best classification performance of the classifier for each pair, and whether that performance is significantly better than random.

Pair Model AUC ACC (%) SPEC (%) SENS (%) p-Value (AUC > Random)
NC vs. sd-aMCI K = 8, γ = 16, C = 1 0.52 50 44 58 >0.05
NC vs. md-aMCI K = 7, γ = 8, C = 100 0.66 61 60 62 <0.05
sd-aMCI vs. md-aMCI K = 7, γ = 4, C = 0.01 0.54 53 53 53 >0.05