Skip to main content
. 2014 Jan 31;11(1):10–16.

Table 1.

Comparison of Initial Forces and Force Loss Over Time of Non-Latex Elastics Between Three Manufacturers

Brand 0 Hour Mean±SD (Range) g 30 min Mean±SD (Range) g 1 Hour Mean±SD (Range) g 3 Hours Mean±SD (Range) g 6 Hours Mean±SD (Range) g 24 Hours Mean±SD (Range) g Repeated Measures ANOVA
P Valued
Forestadent N=20 139.03±6.6 (128–156) 138.58±5.8 (128–152) 128.59±6.8 (117–147) 126.27±7.07 (112–140) 119.52±6.3 (103–131) 86.27±9.9 (68–110) P<0.001
df=5
F=938.5
Ortho Technology N=20 134.25±5.6 (123–141) 132.76±5.6 (119–140) 128.95±7.1 (115–137) 123.66±6.7 (105–132) 119.87±5.9 (105–129) 108.49±5.5 (96–119) P<0.001
df=5
F=301.1
Dentaurum N=20 127.90±12.7 (119–179) 125.24±12.6 (115–175) 120.56±11.9. (109–166) 113.17±11.8 (102–159) 104.85±10.2 (94–143) 100.18±12.1 (82–140) P<0.001
df=5
F=194.8
One Way ANOVA P<0.001 P<0.001 P=0.006 P<0.001 P<0.001 P<0.001
P Value 27.84 211.71 25.64 212.19 224.24 227.34
df
F