Cases of hypertension and associated exposure to different noise frequencies

Characteristics Case group (n = 46) Control group (n = 774) Total subjects (n = 820) P -value
LAeq 8 h (dBA)
 
 
 
 
 Median (Q1, Q3)
81 (79, 82)
79 (77, 82)
79 (77, 82)
0.016a
Frequency components
 
 
 
31.5 Hz (dB)
 
 
 
 
 Median (Q1, Q3)
29 (26, 31)
27 (25, 30)
27 (25, 30)
0.222a
63 Hz (dB)
 
 
 
 
 Median (Q1, Q3)
43 (41, 45)
41 (38, 44)
41 (38, 44)
0.026a
125 Hz (dB)
 
 
 
 
 Median (Q1, Q3)
50 (48, 52)
49 (47, 51)
49 (47, 51)
0.032a
250 Hz (dB)
 
 
 
 
 Median (Q1, Q3)
55 (53, 56)
54 (52, 55)
54 (53, 55)
0.017a
500 Hz (dB)
 
 
 
 
 Median (Q1, Q3)
58 (57, 60)
58 (56, 59)
58 (56, 59)
0.032a
1000 Hz (dB)
 
 
 
 
 Median (Q1, Q3)
61 (60, 63)
61 (59, 63)
61 (59, 63)
0.070a
2000 Hz (dB)
 
 
 
 
 Median (Q1, Q3)
59 (57, 61)
59 (57, 61)
59 (57, 61)
0.120a
4000 Hz (dB)
 
 
 
 
 Median (Q1, Q3)
57 (54, 58)
56 (53, 59)
56 (53, 59)
0.458a
8000 Hz (dB)
 
 
 
 
 Median (Q1, Q3) 50 (48, 52) 49 (45, 52) 49 (45, 52) 0.096a