Patient-Level Diagnostic Accuracy of Cardiac CT–Myocardial Perfusion Imaging (CT-MPI) for and CT Acute Coronary Syndrome

Imaging Protocol No. of Patients Sensitivity Specificity Positive Predictive Value Negative Predictive Value Receiver Operator Curve Area Under the Curve

Cardiac CT 105 100 (66–100) 89 (80–94) 45 (23–69) 100 (96–100) 94 (91–98)
CT-MPI 105 33 (7–70) 100 (96–100) 100 (29–100) 94 (88–98) 67 (50–83)
Cardiac CT plus CT-MPI 105 33 (7–70) 100 (96–100) 100 (29–100) 94 (88–98) 67 (50–83)
> 50% stenosis 20 33 (7–70) 100 (72–100) 100 (29–100) 65 (38–86) 67 (50–0.83)
≤ 50%a 85 100 NA NA 100 NA

Note—Data are percentage (95% CI). NA = not applicable.

a

Because no acute coronary syndrome occurred in the combined cardiac CT plus CT-MPI group with ≤ 50% stenosis, specificity, positive predictive value, receiver operating characteristic, and 95% CI could not be determined.