Skip to main content
. 2012 Mar;16(1):19–39. doi: 10.1177/1084713812445510

Appendix D.

Results of roex Filter Fit for Probe Frequency fp = 2000 Hz

Subject pl pu pu/pl r k ERB BW-3dB
NH 21.6 17.7 0.9 −21.2 −2.4 454.5 360
HI-1 5.3 8.5 1.6 −74.4 −12 1211.1 1026
AMSIM-1 24.6 16.3 0.7 −21.5 −3.9 437 345.3
HI-2 17.1 10.9 0.6 −17 −0.7 670.2 516
AMSIM-2 20.2 13.8 0.7 −78 −0.2 530.1 432
HI-3 17.3 12.2 0.7 −26.7 −3.6 566.6 470
AMSIM-3 18.1 18.2 1 −21.3 0.9 476.9 377.3
HI-4
AMSIM-4 15.7 7.5 0.5 −107 0.7 857.1 689.3
HI-5
AMSIM-5 11.8 8 0.8 −92.5 2.9 1054.6 902
HI-6 13.4 17.3 1.3 −15.1 10.4 638.1 458
AMSIM-6 17.4 8.8 1.1 −130.1 0.5 918.4 787.3
HI-7
AMSIM-7 22.9 13.8 0.7 −62.6 0.5 621.8 489.3
HI-8
AMSIM-8 10.1 7.8 1.2 −83.5 −2 1111.5 931.3
HI-9 33.9 21.3 0.6 −16.8 5.5 383.9 262
AMSIM-9 18.6 19 2.7 −61.1 −0.6 957.1 982
HI-10 24.7 13.1 0.5 −24.3 −4.5 479.7 392
AMSIM-10 25.4 34.9 1.4 −29.3 1.7 318 264

Note: Dash indicates that no valid roex fit was obtained. For normal-hearing (NH), hearing-impaired (HI), and corresponding age-matched, simulated-loss (AM-SIM) listeners, the following parameters are shown: upper and lower slope parameters pl and pu; slope-parameter ratio pu/pl; filter dynamic range r; efficiency term k; equivalent rectangular bandwidth (ERB); and 3-dB-down filter bandwidths (BW-3dB).