Skip to main content
. 2012 Mar;16(1):19–39. doi: 10.1177/1084713812445510

Appendix E.

Results of roex Filter Fit for Probe Frequency fp = 4000 Hz

Subject pl pu pu/pl r k ERB BW-3dB
NH 21.3 49.4 2.5 −25.2 1.8 589.9 472
HI-1 13 21.2 1.6 −16.8 −3.2 1136 844
AMSIM-1 13.8 27.4 2 −69.6 −1.4 927.7 765.3
HI-2 4.8 7 1.5 −148.5 1.2 2760.1 2356
AMSIM-2 11.3 16.8 1.5 −112.7 0.7 1346.4 1082.7
HI-3 7.9 12.9 1.6 −149.7 1 1627.5 1364
AMSIM-3 11.7 25.3 2.3 −67.8 1.1 1077.2 877.3
HI-4 2.4 1.6 0.6 −138.7 5.6 5844.5 7004
AMSIM-4 6.2 21.9 3.7 −107.6 0.3 1766.1 1512
HI-5 4.8 5.5 1.2 −91.2 −3.1 3061.5 2624
AMSIM-5 8.4 14.9 1.8 −112.9 −0.8 1515.6 1268
HI-6
AMSIM-6 4.2 8.9 2 −113.7 3.3 2915.9 2548
HI-7 6.2 42.1 6.8 −10 6.9 2124.6 1384
AMSIM-7 11.3 27.9 3.6 −109.2 1 1342.9 1068
HI-8 6.1 25 4.1 −11.9 6.8 2036.6 1464
AMSIM-8 6.4 25.4 3.9 −108.9 1.7 2049.7 1494.7
HI-9
AMSIM-9
HI-10 12.6 32.5 2.6 −161.6 −2.7 881.7 736
AMSIM-10 16 29.1 1.8 −67.4 −0.6 868.1 694.7

Note: Dash indicates that no valid roex fit was obtained. For normal-hearing (NH), hearing-impaired (HI), and corresponding age-matched, simulated-loss (AM-SIM) listeners, the following parameters are shown: upper and lower slope parameters pl and pu; slope-parameter ratio pu/pl; filter dynamic range r; efficiency term k; equivalent rectangular bandwidth (ERB); and 3-dB-down filter bandwidths (BW-3dB).