Appendix E.
Results of roex Filter Fit for Probe Frequency fp = 4000 Hz
Subject | pl | pu | pu/pl | r | k | ERB | BW-3dB |
---|---|---|---|---|---|---|---|
NH | 21.3 | 49.4 | 2.5 | −25.2 | 1.8 | 589.9 | 472 |
HI-1 | 13 | 21.2 | 1.6 | −16.8 | −3.2 | 1136 | 844 |
AMSIM-1 | 13.8 | 27.4 | 2 | −69.6 | −1.4 | 927.7 | 765.3 |
HI-2 | 4.8 | 7 | 1.5 | −148.5 | 1.2 | 2760.1 | 2356 |
AMSIM-2 | 11.3 | 16.8 | 1.5 | −112.7 | 0.7 | 1346.4 | 1082.7 |
HI-3 | 7.9 | 12.9 | 1.6 | −149.7 | 1 | 1627.5 | 1364 |
AMSIM-3 | 11.7 | 25.3 | 2.3 | −67.8 | 1.1 | 1077.2 | 877.3 |
HI-4 | 2.4 | 1.6 | 0.6 | −138.7 | 5.6 | 5844.5 | 7004 |
AMSIM-4 | 6.2 | 21.9 | 3.7 | −107.6 | 0.3 | 1766.1 | 1512 |
HI-5 | 4.8 | 5.5 | 1.2 | −91.2 | −3.1 | 3061.5 | 2624 |
AMSIM-5 | 8.4 | 14.9 | 1.8 | −112.9 | −0.8 | 1515.6 | 1268 |
HI-6 | — | — | — | — | — | — | — |
AMSIM-6 | 4.2 | 8.9 | 2 | −113.7 | 3.3 | 2915.9 | 2548 |
HI-7 | 6.2 | 42.1 | 6.8 | −10 | 6.9 | 2124.6 | 1384 |
AMSIM-7 | 11.3 | 27.9 | 3.6 | −109.2 | 1 | 1342.9 | 1068 |
HI-8 | 6.1 | 25 | 4.1 | −11.9 | 6.8 | 2036.6 | 1464 |
AMSIM-8 | 6.4 | 25.4 | 3.9 | −108.9 | 1.7 | 2049.7 | 1494.7 |
HI-9 | — | — | — | — | — | — | — |
AMSIM-9 | — | — | — | — | — | — | — |
HI-10 | 12.6 | 32.5 | 2.6 | −161.6 | −2.7 | 881.7 | 736 |
AMSIM-10 | 16 | 29.1 | 1.8 | −67.4 | −0.6 | 868.1 | 694.7 |
Note: Dash indicates that no valid roex fit was obtained. For normal-hearing (NH), hearing-impaired (HI), and corresponding age-matched, simulated-loss (AM-SIM) listeners, the following parameters are shown: upper and lower slope parameters pl and pu; slope-parameter ratio pu/pl; filter dynamic range r; efficiency term k; equivalent rectangular bandwidth (ERB); and 3-dB-down filter bandwidths (BW-3dB).