Skip to main content
. 2013 Nov 4;14(6):177–194. doi: 10.1120/jacmp.v14i6.4363

Table 2.

Average displacement errors (mm) and standard deviations for DMP and Demons registrations evaluated with different patient images

Image Set Patient Volume Lung
(motion magnitude) DMP Demons DMP Demons
Lung1 (30 mm)
1.3±1.1
1.1±1.0
1.0±0.7
0.8±0.6
Lung2 (27 mm)
2.2±1.2
5.2±5.4
2.4±1.1
2.3±1.2
Lung3 (30 mm)
2.6±1.7
2.1±1.3
2.4±1.3
1.9±0.7
Lung4 (30 mm)
2.4±2.3
30.0±18.1
1.7±1.0
9.3±6.3