Skip to main content
NIHPA Author Manuscripts logoLink to NIHPA Author Manuscripts
. Author manuscript; available in PMC: 2015 Mar 30.
Published in final edited form as: Rapid Commun Mass Spectrom. 2014 Mar 30;28(6):653–661. doi: 10.1002/rcm.6816

Evaporative Derivatization of Phenols with 2-Sulfobenzoic Anhydride for Detection by MALDI-MS

Yuanyuan Yao 1, Poguang Wang 1, Roger Giese 1,*
PMCID: PMC4041620  NIHMSID: NIHMS557842  PMID: 24519828

Abstract

RATIONALE

Phenols are an important class of analytes, for example as bioactive environmental contaminants. Towards a goal of improving their detection by MALDI-TOF-MS or MALDI-TOF/TOF-MS, we studied their derivatization with 2-sulfobenzoic anhydride (SBA). We chose SBA for this purpose since it is commercially available, inexpensive, and forms an anionic derivative.

METHODS

In selected conditions developed here for phenols, a reaction mixture of one or more of such compounds in acetonitrile containing SBA and 4-dimethylaminopyridine (DMAP) is evaporated to a solid, heated at 60°C for 1 h, redissolved in 50% acetonitrile containing matrix, spotted onto a MALDI target, and subjected to negative ion MALDI-TOF/TOF-MS.

RESULTS

While conventional (solution-phase) reaction of 4-phenylphenol (model analyte) with SBA and DMAP only gave a 47% yield of SBA-tagged 4-phenylphenol, evaporative derivatization as above gave a 96% yield, and 25 pmol (4.3 ng) of 4-phenylphenol could be detected in this way by MALDI-TOF/TOF-MS at S/N = 260, whereas even 1 nmol of the nonderivatized phenol was not detected in the absence of derivatization. A wide range of responses was observed when a mixture of 15 phenols was derivatized, with the higher responses coming from phenols with a pKa value above 9. Without derivatization, phenols with pKa values below 5 were the most readily detected.

CONCLUSION

Evaporative derivatization with SBA (a convenient reagent) can improve the detection of phenols with relatively high pKa values (above 9) by negative ion MALDI-TOF-MS, and accomplish this in the absence of post-derivatization reaction cleanup.

Keywords: Phenols, derivatization, 2-sulfobenzoic anhydride, mass spectrometry

INTRODUCTION

As has been reviewed,[1] ionic tagging of small molecules to increase their response by soft ionization techniques such as ESI and MALDI is of increasing interest. Other benefits can accrue such as increased selectivity. One of the reagents which has been studied in this way is 2-sulfobenzoic anhydride (SBA). While the compound is commercially available and relatively inexpensive, it has been explored to a limited degree in terms of the number of publications reporting its analytical use; how much it enhances analyte response; and its performance when applied to a small amount of analyte.

In more detail, the analytical studies of SBA to date are as follows. Peptides were tagged with SBA to improve their fragmentation (for sequencing purposes) in the post source decay positive ion mode of MALDI.[2,3] SBA has been used to derivatize a diversity of alcohols (including phenol, glucose, and mandelic acid) for detection by negative ion MALDI-TOF-MS.[4] Multiple products were reported from multi-hydroxy compounds, whose formation was attributed to steric effects. The amount of each alcohol reacted (calculated per hydroxy function) was 0.1 mmol. Yields were not defined. The LOD was reported as 2.5 pmol for SBA-tagged methanol, based on testing a diluted reaction mixture, assuming a reaction yield of 100%; apparently this value was obtained by extrapolating from a measurement at a higher concentration. It was not clear whether a blank sample was derivatized to rule out contamination. Zu and coworkers derivatized fatty alcohol ethoxylate non-ionic surfactants at the 0.05 mmol level using SBA in the presence of 4-dimethylaminopyridine (DMAP), followed by diluting the reaction mixture and subjecting it to LC/ESI-MS or flow injection ESI-MS.[5] The yield was reported to be about 95% based on the assumption that the product (SBA-tagged alcohol) and starting alcohol gave the same response by ESI-MS. SBA has also been used to modify proteins[6,7] and industrial polymers.[8]

Towards a goal of improving the detection of phenols by MALDI-MS, we have extended the work of others concerning derivatization with SBA, and this manuscript reports our progress. The detection of phenols is of broad interest mainly because some are bioactive as biomolecules or xenobiotics. Mass spectrometry is used commonly to detect phenols in both of these roles, usually as part of a GC/MS[912] or LC/MS[1316] system.

EXPERIMENTAL

Materials

4-Phenylphenol (4PP), 4-nonylphenol, bisphenol A (BPA), 2-sulfobenzoic anhydride (SBA), 4-dimethylaminopyridine (DMAP), acetonitrile (ACN, anhydrous, 99.8%), and α-cyano-4-hydroxycinnamic acid (CCA), were from Sigma-Aldrich (St. Louis, MO, USA). CCA matrix was 5 mg/mL of CCA in ACN/H2O (1:1, v/v). Phenol Calibration Mix (12 components Cat. No. 31694) was purchased from Restek (Bellefonte, PA, USA). Water (distilled, HPLC grade) and acetonitrile (HPLC grade) were purchased from Thermo Fisher Scientific (Waltham, MA, USA). Glass vials with inserts (product No. 09-1200-101) and screw thread caps (product No. 09-0040R) were purchased from Microliter Analytical Supplies (Suwanee, GA, USA).

Non-evaporative derivatization of 4-phenylphenol with SBA

The conditions of Zu and coworkers[5] for derivatization of polyols with SBA were employed. Briefly, 4PP (8.5 mg, 0.05 mmol), SBA (92 mg, 0.5 mmol), and DMAP (0.1 mg, 8.2×10−4 mmol, 1% w/w of 4PP) were dissolved in 1 mL of ACN. After sitting at room temperature for 1 h, the mixture was kept at 80°C for 2 h. The reaction was also conducted at room temperature for 24 h. After the reaction, the mixture was diluted 100-fold with ACN/H2O (20:80, v/v) for HPLC analysis.

Evaporative derivatization of 4-phenylphenol with SBA

4PP was used as a model phenol to optimize the conditions for evaporative derivatization. For the initial studies, one equivalent of 4PP and ten equivalents of SBA were combined in 2% (w/w of 4PP) of DMAP in 1 mL ACN to reach a concentration of 4PP (5×10−2 M, 5×10−3 M, and 5×10−4 M). A 50 µL aliquot was pipetted into a glass vial having an insert and evaporated in a Speed Vac (Savant Instruments, Saroor Nagar, Hyderbad, India; the manufacture-specified vacuum was 0.6 torr) at room temperature for 40 minutes. The resulting solid was incubated at 60°C in a sand bath (Reacti-therm, Pierce, Rockford, IL, USA) for 1 h with the bottom of the cap 4 mm above the sand. For subsequent HPLC-UV analysis after derivatization, each reaction mixture was dissolved in 50 µL of 50% ACN. The reaction mixtures with initial 4PP concentrations of 5×10−2 M, 5×10−3 M, and 5×10−4 M were diluted, respectively, 100-fold, 10-fold and 10-fold with ACN/H2O (20:80, v/v) prior to HPLC analysis. In addition, 5 µL of a reaction mixture having 5×10−6 M 4PP along with 5×10−3 M SBA and 1.6×10−7 M DMAP was subjected to evaporative derivatization prior to addition of 10 µL of CCA matrix and deposition of 1 µL onto the target plate for analysis by MALDI-MS.

Evaporative derivatization of fifteen phenols with SBA

A mixture of 15 phenols (4PP, 4-nonylphenol, BPA, and a 12-component Phenols Calibration Mix) in 1 mL of ACN was set up as follows: 5×10−4 M each component phenol, 5×10−3 M SBA, and 2% (w/w of total phenols) DMAP. A 50 µL aliquot was evaporated and heated at 60°C for 1 h followed by dissolving in 50 µL of ACN /H2O (1:1), and 1 µL was then combined with 10 µL of CCA for subsequent analysis of 1 µL by MALDI-MS.

Analysis by HPLC-UV

A 10-µL aliquot of the diluted sample after derivatization was injected into a Hewlett Packard Series 1100 HPLC system. The HPLC column was an AQUASIL (Thermo Fisher Scientific) C18 column (150 × 2.1 mm, 5 µm) that was kept at room temperature and operated at a flow rate of 0.21 mL/min. Before each run, the column was equilibrated for 10 min with 2:98, v/v, ACN/H2O. The following solvent gradient was applied: 2% ACN for 3 min, ramp to 50% ACN over 13 min, hold for 4 min, ramp to 100% ACN over 5 min, and hold for 5 min. Absorbance detection was at 256 nm.

Analysis by MALDI-MS (MALDI-TOF-MS or MALDI-TOF/TOF-MS)

MALDI-MS analysis was performed on a Model 5800 MALDI-TOF/TOF-MS instrument (AB SCIEX, Framingham, MA, USA) in negative ion, reflectron mode with a delay time of 100 ns, with 1200 laser pulses being averaged to generate a spectrum. MS/MS was performed by TOF/TOF with the metastable-suppressor on and the CID off. A mass resolution window of 400 (instrumental setting) was used. This setting (viz. 400) combined with the precursor ion mass defines the mass window for MS2 (done automatically by the software). The relative laser intensity was set at ~2500 for MS mode and ~ 3500 for MS/MS mode. For the direct analysis of the derivatized phenol mixture, a 1 µL aliquot of the redissolved reaction mixture in ACN/H2O (1:1, v/v) was mixed with 10 µL CCA matrix, and 1 µL was deposited onto the MALDI plate. For the analysis of the collected HPLC peak fraction for SB-4PP after the derivatization reaction, 10 µL CCA matrix was added to the dried fraction, and 1 µL was deposited onto the MALDI plate.

Evaporative derivatization of pentachlorophenol with SBA

This reaction was conducted on 50 µL of 0.05 M pentachlorophenol in the same way as the corresponding sample of 4PP described above, except that, in addition to a reaction time of 1 h at 60°C, reaction temperatures of 80°C and 100°C were studied. This was followed by HPLC-UV analysis and, in turn, peak collection for analysis by MALDI-TOF, as above for 4PP.

RESULTS AND DISCUSSION

To optimize the derivatization of phenols by SBA, we initially tested 4-phenylphenol (4PP) as a model analyte, and relied on HPLC-UV and/or MALDI-MS to assess the product mixture. A scheme for the derivatization and analysis of this (and later other phenols) by MALDI-MS is shown in Fig. 1. At first we studied the two kinds of reaction conditions reported by Zu and coworkers.[5] Since both the 4PP and the desired product, SBA-tagged 4-phenylphenol (SB-4PP), have relatively simple structures, and the HPLC chromatograms displayed no significant side products, we relied on the disappearance of the peak for 4PP to estimate the yield. (This way of assessing the yield is validated further below.) By this strategy, the yield of SB-4PP was about 52% (n=3, CV=6%) when the reaction was conducted by keeping it at room temperature for 1 h prior to heating it at 80°C (one type of condition employed previously[5]). A representative HPLC chromatogram from this experiment is shown in Fig. 2A, along with that from an unheated reaction at time zero (inset of Fig. 2A). Peak 1 was confirmed to be SB-4PP by collecting it and subjecting it to MALDI-TOF-MS and MALDI-TOF/TOF-MS analysis (see below). Conducting the reaction at room temperature for 24 h (second type of condition reported previously[5]) gave a yield of 3% (n=3, CV=0.17%); data not shown.

Figure 1.

Figure 1

Scheme for detection of phenols by derivatization with 2-sulfobenzoic anhydride (SBA) followed by mass spectrometry, where MS designates MALDI-TOF-MS, and MS/MS designates MALDI-TOF/TOF-MS, each in negative ion mode.

Figure 2.

Figure 2

HPLC chromatograms of reaction mixtures of 4PP, SBA and DMAP: (A) Nonevaporative derivatization where the reaction mixture was heated at 80°C for 2 h; and (B) Evaporative derivatization where the reaction mixture was evaporated and then heated at 60°C for 1 h. Peak 1: SB-4PP; peak 2: 4PP. HPLC conditions: see EXPERIMENTAL. Insets: unheated reactions at time zero.

We next explored “evaporative derivatization conditions” to potentially improve the yield (by increasing the concentration of the reagent, and perhaps also by creating a different reaction microenvironment), and also potentially to facilitate or even avoid post-derivatization sample cleanup (by minimizing the amounts of the derivatization reagents) when 4PP is reacted with SBA. The reaction mixture was evaporated prior to incubating it at room temperature or at an elevated temperature. We initially tested the following concentrations of reactants in acetonitrile (same as those tested above) prior to evaporation: 5×10−2 M 4PP, 5×10−1M SBA, and 1.6×10−3 M DMAP. Evaporation of a 50-µL aliquot of a 1 mL reaction solution was carried out at room temperature for 40 min at 0.6 torr, yielding a solid. Keeping this solid at room temperature for 3 d gave a 48% yield of SB-4PP based on HPLC-UV (the yield progressively climbed to this level during this period of time; data not shown). A longer reaction time at room temperature was not studied.

The evaporative derivatization reaction was faster and the yield was higher at an elevated temperature. After studying various times and temperatures (see below), we selected 1 h at 60°C, which gave a yield of 96% (n = 3, CV=1%), since the other conditions tried (longer times and higher temperatures) gave little improvement in yield, and a higher temperature or longer time risks an increase in noise. A representative HPLC chromatogram is shown in Fig. 2B, along with that from an unheated reaction at time zero in the inset. The early-eluting peak in Fig. 2B was 10% higher when the phenol was not present in the reaction mixture (unreacted or hydrolyzed reagents contributed to this peak, so the peak was slightly increased in the blank since some of these reagents had reacted with the phenol). This further validated our way of assessing the yield. Examples of results from other conditions are as follows (expressed as mean ± CV) where the reaction time was 2 h and n = 3 in each case: 59 ± 1% at 40°C, 97 ± 0.2% at 60°C, and 98 ± 0.3% at 80°C (data not shown). Direct analysis of the evaporative reaction mixture (after addition of CCA matrix), using the condition 60°C for 1 h, by MALDI-TOF-MS, gave the data shown in Fig. 3A, with a peak for deprotonated SB-4PP at m/z 353.050 (exact mass 353.048), and the data from a blank reaction (no 4PP) in Fig. 3B. (The isotope peak at m/z 354.050 in Fig. 3A falsely appears to be too high since the corresponding nonisotopic peak is saturated.) Corresponding data by MALDI-TOF/TOF-MS are shown in Fig. 4A (showing a peak for the 4-phenylphenolate product ion at m/z 169 derived from the deprotonated molecule at m/z 353) and in Fig. 4B (blank: no 4PP).

Figure 3.

Figure 3

Negative ion MALDI-TOF-MS spectra. (A) reaction mixture of 4PP and SBA after 1 μL was combined with 10 μL CCA matrix and spotted onto the target for MALDI-TOF-MS giving a peak for deprotonated SB-4PP at m/z 353.050 (exact mass 353.048); the reaction was conducted by non-evaporative derivatization at 60 °C for 1 h with the initial reaction mixture of 5×10−2M: 4PP, 5×10−1M SBA, and 1.6 ×10−3M DMAP. (B) 1 μL of ACN combined with CCA matrix, showing an absence of this peak.

Figure 4.

Figure 4

Negative ion MALDI-TOF/TOF-MS spectra of: (A) same sample as in Figure 3A; and (B) same sample as in Figure 3B, after selection of the deprotonated SB-4PP precursor ion at m/z 353.

The reaction of 4PP with SBA was next studied at lower concentrations of 4PP under the selected reaction conditions (60°C, 1 h), while also lowering the concentration of SBA and DMAP, but keeping the relative molar amounts of 4PP, SBA, and DMAP constant (1:10:0.03). We observed by HPLC-UV that the yield of SB-4PP was unchanged even when the following concentrations were set up prior to evaporation: 5×10−4 M 4PP, 5×10−3M SBA, and 1.6×10−5 M DMAP. Lower concentrations (with the usual dilution after the reaction) than this of 4PP could not be detected reliably by HPLC-UV. However, SB-4PP product (at m/z 353.050) could be detected by both MALDI-TOF-MS (Fig. 5A) and MALDI-TOF/TOF-MS (peak at m/z 169 in Fig. 5B), even when the following initial solution concentrations were tested: 5×10−6 M 4-PP, 5×10−3 M SBA, and 1.6×10−7 M DMAP. Since the volume of this reaction solution prior to evaporation was 50 µL, about 43 ng of 4PP was detected in this way. While evaporating 5 µL of this reaction solution (containing 4.3 ng or 25 pmol) did not yield a peak for the product by MALDI-TOF-MS, detection by MALDI-TOF/TOF-MS was successful (S/N = 260 for m/z 169), as seen in spectrum a in the inset of Fig. 5B, where the spectrum from the blank reaction (no 4PP) is also shown (spectrum b in the inset of Fig. 5B).

Figure 5.

Figure 5

(A): Negative ion MALDI-TOF-MS spectrum after evaporative derivatization at 60 °C for 1 h with the initial reaction mixture of 50 μL 5×10−6M 4PP, 5×10−3M SBA, and 1.6 ×10−7M DMAP, showing a peak for deprotonated SB-4PP at m/z 353.050. (B) Negative ion MALDI-TOF/TOF-MS spectrum of the same sample after selection of the ion at m/z 353 for deprotonated SB-4PP, showing a peak at m/z 169 for the phenolate product ion of SB-4PP (see Figure 1). Inset of (B): Spectrum a: negative ion MALDI-TOF/TOF-MS spectrum after evaporative derivatization 60°C for 1 h of an initial reaction mixture of 5 μL 5×10−6M 4PP, 5 ×10−3M SBA, and 1.6×10−7M DMAP; the peak at m/z 169 has a S/N of 260. Spectrum b: blank reaction (no 4PP).

Evaporative derivatization of a mixture of phenols

A mixture of 15 phenols (structures shown in Table 1) was reacted with SBA under evaporative derivatization conditions, where the concentration of each phenol was 5×10−4 M in the 50-µL solution prior to evaporation, and the corresponding concentrations of SBA and DMAP were 5×10−3 M and 1.6×10−5 M, respectively. The relative responses (relative to 4-nonylphenol; see below) of the products were obtained by directly subjecting an aliquot of the reaction mixture, after matrix addition, to MALDI-TOF-MS and MALDI-TOF/TOF-MS, giving the data shown in Fig. 6. This data is tabulated in Table 1, along with the pKa values of the phenols. Note that the values for relative response in the table reflect the combined variation in both reaction yield and S/N by the two MALDI techniques. The response of 4-nonylphenol was arbitrarily assigned a value of 100 independently for both the TOF and the TOF/TOF data since it gave the highest S/N in each case. The nature of the cited ions is defined generically in Fig. 1. Overall, it is clear that phenols can differ widely in their response by the method presented here.

Table 1.

Relative yield/response values by MALDI-MS (data from Figure 6) for phenols after evaporative derivatization with SBA.a

Number Structure Deprotonated
molecule by TOF
(m/z)
R-Phenolate by
TOF/TOF
(m/z)
pKa
1 graphic file with name nihms557842t1.jpg 100 (403.158) 100 (219.17) 10.4
2 graphic file with name nihms557842t2.jpg 29.5 (353.048) 16.5 (169.07) 9.6
3 graphic file with name nihms557842t3.jpg 25.0 (305.048) 4.0 (121.07) 10.6
4 graphic file with name nihms557842t4.jpg 12.3 (324.994) 3.8 (141.01) 9.6
5 graphic file with name nihms557842t5.jpg 11.6 (411.090) 7.1 (227.11) 9.6, 11.3
6 graphic file with name nihms557842t6.jpg 8.6 (291.033) 1.1 (107.05) 10.3
7 graphic file with name nihms557842t7.jpg 6.4 (277.017) 1.0 (93.03) 10.0
8 graphic file with name nihms557842t8.jpg 0.3 (344.939) 0.1 (160.96) 7.9
9 and 10 graphic file with name nihms557842t9.jpg 0.1 (322.002) 0.2 (138.02) 7.2
11 graphic file with name nihms557842t10.jpg N/D (381.003) N/D (197.02) 4.3
12 graphic file with name nihms557842t11.jpg N/D (366.987) N/D (183.00) 4.1
13 graphic file with name nihms557842t12.jpg N/D (310.978) N/D (127.00) 8.6
14 graphic file with name nihms557842t13.jpg N/D (378.900) N/D (194.92) 6.1
15 graphic file with name nihms557842t14.jpg N/D (446.822) N/D (262.84) 4.7
a

Names of compounds: 1) 4-nonylphenol; 2) 4-phenylphenol (4PP); 3) 2,4-dimethylphenol; 4) 4-chloro-3-methylphenol; 5) bisphenol A (BPA); 6) o-cresol; 7) phenol; 8) 2,4-dichlorophenol; 9) 2-nitrophenol; 10) 4-nitrophenol; 11) 2-methyl-4,6-dinitrophenol; 12) 2,4-dinitrophenol; 13) 2-chlorophenol; 14) 2,4,6-trichlorophenol; 15) pentachlorophenol.

b

ND: not detected or not readily detected.

Figure 6.

Figure 6

Negative ion MALDI-TOF-MS spectra of: (A) reaction mixture of 15 phenols (see Table 1) in which evaporative derivatization with SBA (5×10−3M) and DMAP (2% w/w of total phenols) was performed at 60°C for 1 h, where each phenol was 5×10−4M; and (B) reaction blank (phenols not present).

There could be several reasons that eight of the phenols (8–15) gave little or no response by MALDI-TOF-MS after derivatization with SBA, such as incomplete derivatization, instability of the derivatives in the MALDI step, and variation in the efficiency of desorption. It is interesting that all these compounds have relatively low pKa values (below 9). We tested pentachlorophenol with reaction monitoring by HPLC-UV, and HPLC-peak collection-MALDI-MS, to gain some insight. The yield of SBA-tagged pentachlorophenol was about 1% at 60°C, about 2% at 80°C, and about 25% at 100°C after 2 h of an evaporative derivatization reaction, based on disappearance of the peak for starting material. Longer reaction times increased the formation of side products without significantly increasing the yield. The HPLC chromatogram from the latter reaction (100°C, 2h) is shown in Fi. 7. The new peak (peak 1) was confirmed to be SBA-tagged pentachlorophenol by collection and analysis by MALDI-TOF-MS in positive ion mode, giving an ion for [M − H + 2 Na]+ at m/z 492.810 (exact mass 492.801; data not shown). The observed isotope pattern of this deprotonated disodiated molecule matched the calculated isotope pattern (data not shown).

Figure 7.

Figure 7

HPLC chromatogram of the reaction mixture of pentachlorophenol, SBA and DMAP after evaporative derivatization at 100° C for 1 h. Peak 1: SBA-derivatized pentachlorophenol. Peak 2: underivatized pentachlorophenol. Concentrations and HPLC conditions: see EXPERIMENTAL.

In negative ion mode, no deprotonated molecule was observed from the collected HPLC peak (peak 1 in Figure 7) from the above reaction of pentachlorophenol; instead peaks for [C6Cl5O] (m/z 264.839), [C6Cl5O + CCA − H + Na] (475.853), and [C6Cl5O + C6Cl5O + Na] (552.651) were seen (data not shown); peak ratio 7:6:2. This prompted us to re-evaluate the MALDI-TOF-MS data related to pentachlorophenol from the reaction mixture of 15 phenols. Indeed, peaks for [C6Cl5O] and [C6Cl5O + CCA − H + Na] were seen. For pentachlorophenol, one can speculate that the failure to readily detect the derivatized compound in the reaction of 15 phenols, according to the strategy summarized in Table 1, was mainly due to a combination of low reaction yield (apparently from steric and/or inductive effects), spread of the signal in MALDI-TOF-MS over several ions including isotope peaks, and pronounced instability of the deprotonated molecule in the ion source. To different degrees, these same factors may contribute to the behavior of the other phenols in Table 1 that gave little or no response under the conditions employed. Overall, it is seen that the phenols with a relatively high pKa values (above 9, compounds 1–7) are much more detectable (> 10 fold) than those with pKa values below 9 (compounds 8–15). The highest responders are monophenols with a higher degree of alkyl or aryl bulk, and a pKa above 9 (compounds 1–3).

We also tested the nonderivatized phenols by negative ion MALDI-MS. The amount of each compound applied to the target was 1 nmol irrespective of whether it was tested individually (compounds 1, 2, 5 and 15) or as a mixture (compounds 3, 4, and 6–15). At a laser setting of 3800, the compounds either gave no response (compounds 1, 2, 5 and 6); encountered matrix interference (3 and 7); gave a weak signal (S/N = 77 for 4, 43 for 8, 47 for 13, and 121 for 14); gave a strong signal (compounds 9 and 10, S/N = 1100); or gave a saturated (off-scale) signal (11, 12 and 15). The highest laser setting (2400) that kept the peak on scale for compound 15 (S/N = 1460) resulted in a loss of signal for compounds 4, 8, 9, 10 and 14, while the peaks for compounds 11 and 12 were still off scale. Reducing the laser setting to 2200 brought the peaks for 11 and 12 on scale (S/N = 1860 and 1760, respectively) and lowered the S/N of compound 15 to 219. We note that the highest responders (11, 12 and 15) have the lowest pKa values (4.1– 4.7). Overall, derivatization with SBA therefore is somewhat complementary to detection by negative ion MALDI-MS without derivatization, since phenols giving little or no response when underivatized (compounds 1, 2, 4, 5, 6) tended to be readily or highly detected after derivatization (compounds 1–7).

CONCLUSIONS

2-Sulfobenzoic anhydride has some properties, either well-known or introduced here, that encourage its further study as an analytical derivatization reagent for phenols with a relatively high pKa (above 9) to improve their detection by negative ion MALDI-MS: commercial availability at low cost; high reaction yield by evaporative derivatization; and effectiveness under this condition without post-derivatization sample cleanup. In the absence of derivatization, phenols with pKa values below 5 were the most readily detected.

ACKNOWLEDGEMENTS

This work was supported by NIH Grant P42ES017198 from NIEHS. This is contribution number 1040 from the Barnett Institute.

LITERATURE CITED

  • 1.Zaikin V, Halket J. A Handbook of Derivatives for Mass Spectrometry. UK: IM Publications; 2009. Soft ionization mass spectrometry of small molecules, in; pp. 237–297. [Google Scholar]
  • 2.Keough T, Youngquist RS, Lacey MP. A Method for high-sensitivity peptide sequencing using postsource decay matrix-assisted laser desorption ionization mass spectrometry. Proc. Natl. Acad. Sci. 1999;96:7131. doi: 10.1073/pnas.96.13.7131. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3.Stegemann C, Tsvetkova EV, Aleshina GM, Lehrer RI, Kokryakov VN, Hoffmann R. De novo sequeicing of two new cyclic theta defensins from baboon (Papio Hamadryas) leukocytes by matrix-assisted laser desorption/ionization mass spectrometry. Rapid Commun. Mass. Spectrom. 2010;15:599. doi: 10.1002/rcm.4424. [DOI] [PubMed] [Google Scholar]
  • 4.Tholey A, Wittmann C, Kang M-J, Bungert D, Hollemeyer K, Heinzle E. Derivatization of small biomolecules for optimized matrix-assisted laser desorption/ionization mass spectrometry. J. Mass Spectrom. 2002;37:963. doi: 10.1002/jms.355. [DOI] [PubMed] [Google Scholar]
  • 5.Zu C, Praay HN, Bell BM, Redwine OD. Derivatization of fatty alcohol ethoxylates non-ionic surfactants using 2-sulfobenzoic anhydride for characterization by liquid chromatography/mass spectrometry. Rapid Commun. Mass Spectrom. 2010;24:120. doi: 10.1002/rcm.4367. [DOI] [PubMed] [Google Scholar]
  • 6.Bagree A, Sharma IK, Gupta KC, Narang CK, Saund AK, Mathur NK. Modification of ε-amino group of lysine in proteins by acylation with pyromellitic dianhydride and o-sulphobenzoic anhydride. FEBS Letters. 1980;120:275. doi: 10.1016/0014-5793(80)80315-2. [DOI] [PubMed] [Google Scholar]
  • 7.Moulin A, Fourneron JD, Pieroni G, Verger R. Interface-mediated inactivation of pancreatic lipase by a water-reactive compound: 2-sulfobenzoic cyclic anhydride. J. Biochem. 1989;25:6340. doi: 10.1021/bi00441a029. [DOI] [PubMed] [Google Scholar]
  • 8.Vo C-D, Iddon PD, Armes SP. Esterfication of hydroxylated polymers with 2-sulfobenzoic acid cyclic anhydride: A facile approach for the synthesis of near-monodisperse strong acid homopolymers and diblock copolymers. Polymer. 2007;48:1193. [Google Scholar]
  • 9.Cacho JI, Campillo N, Vinas P, Hernandez-Cordoba M. Determination of alkylphenols and phthalate esters in vegetables and migration studies from their packages by means of stir bar sorptive extraction coupled to gas chromatography-mass spectrometry. J. Chromatogr. A. 2012;1241:21. doi: 10.1016/j.chroma.2012.04.018. [DOI] [PubMed] [Google Scholar]
  • 10.Faludi T, Andrasi N, Vasanits-Zsigrai A, Gy, Zaray, Molnar-Perl I. Systematic derivatization, mass fragmentation and acquisition studies in the analysis of chlorophenols, as their silyl derivatives by gas chromatography-mass spectrometry. J. Chromatogr. A. 2013;1302:133. doi: 10.1016/j.chroma.2013.06.004. [DOI] [PubMed] [Google Scholar]
  • 11.Kojima M, Tsunoi S, Tanaka M. High performance solid-phase analytical derivatization of phenols for gas chromatography-mass spectrometry. J. Chromatogr. A. 2004;1042:1. doi: 10.1016/j.chroma.2004.05.012. [DOI] [PubMed] [Google Scholar]
  • 12.Kovacs A, Kende A, Mortl M, Volk G, Rikker T, Torkos K. Determination of phenols and chlorophenols as trimethylsilyl derivatives using gas chromatography-mass spectrometry. J. Chromatogr. A. 2008;1194:139. doi: 10.1016/j.chroma.2008.04.043. [DOI] [PubMed] [Google Scholar]
  • 13.Salgueiro-Gonzalez N, Turnes-Carou I, Muniategui-Lorenzo S, Lopez-Mahia P. Membrane assisted solvent extraction coupled with liquid chromatography tandem mass spectrometry applied to the analysis of alkylphenols in water samples. J. Chromatogr. A. 2013;1281:46. doi: 10.1016/j.chroma.2013.01.069. [DOI] [PubMed] [Google Scholar]
  • 14.Feo ML, Baron E, Aga DS, Eljarrat E, Barcelo D. Development of a liquid chromatography-electrospray chemical ionization tandem mass spectrometry analytical method for analysis of eleven hydroxylated polybrominated diphenyl ethers. J. Chromatogr. A. 2013;1301:80. doi: 10.1016/j.chroma.2013.05.062. [DOI] [PubMed] [Google Scholar]
  • 15.Zhou F, Zhang L, Liu A, Shen Y, Yuan J, Yu X, Feng X, Xu Q, Cheng C. Measurement of phenolic environmental estrogens in human urine samples by HPLC-MS/MS and primary discussion the possible linkage with uterine leiomyoma. J. Chromatogr. B. 2013;938:980. doi: 10.1016/j.jchromb.2013.08.032. [DOI] [PubMed] [Google Scholar]
  • 16.Santos SAO, Vilela C, Freire CSR, Pscoal Neto C, Silvestre AJD. Ultra-high performance liquid chromatography coupled to mass spectrometry applied to the identification of valuable phenolic compounds from Eucalyptus wood. J. Chromatogr. B. 2013;938:965. doi: 10.1016/j.jchromb.2013.08.034. [DOI] [PubMed] [Google Scholar]

RESOURCES