TABLE 5.

Performance characteristics of combined use of CareStart and OptiMAL-IT RDTs compared with those of microscopy for the diagnosis of P. knowlesi malaria

Method and result No. of patients with:
% Sensitivity (CI) % Specificity (CI) % PPVb (CI) % NPVc (CI) Likelihood ratio
PCR-confirmed P. knowlesi PCR-confirmed other Plasmodium species Positive test Negative test
RDTsa
    Positive 45 5 25 (19–32) 96 (91–99) 90 (78–97) 47 (40–53) 6.17 0.78
    Negative 136 119
Microscopy
    Positive 143 15 74 (67–80) 89 (82–94) 91 (85–95) 70 (63–77) 6.57 0.29
    Negative 50 118
a

Equivocal result for VOM-pLDH, negative result for Pf-HRP2, equivocal result for pan-pLDH, and positive result for Pf-pLDH.

b

PPV, positive predictive value.

c

NPV, negative predictive value.