Table 4.
AUC | 95% CI | Z-statistic | P-value (area =0.5) | Youden index J | Associated criterion | Sensitivity | Specificity | |
---|---|---|---|---|---|---|---|---|
MLD (cGy) | 0.878±0.0829 | 0.680–0.975 | 4.559 | <0.0001 | 0.6889 | >1,027 | 88.9 | 80.0 |
V5 (%) | 0.815±0.113 | 0.605–0.942 | 2.782 | 0.0054 | 0.7111 | >44 | 77.8 | 93.3 |
V10 (%) | 0.819±0.104 | 0.609–0.944 | 3.055 | 0.0022 | 0.6222 | >29 | 88.9 | 73.3 |
V15 (%) | 0.822±0.0985 | 0.613–0.947 | 3.270 | 0.0011 | 0.6000 | >27 | 66.7 | 93.3 |
V20 (%) | 0.889±0.0771 | 0.694–0.979 | 5.044 | <0.0001 | 0.7111 | >22 | 77.8 | 93.3 |
V30 (%) | 0.881±0.0692 | 0.684–0.976 | 5.514 | <0.0001 | 0.6000 | >17 | 66.7 | 93.3 |
Abbreviations: ROC, receiver operating characteristic; AUC, area under the curve; CI, confidence interval; MLD, mean lung dose.