Table 2.

Summary of characterization data for cl-micelles by TEM, AFM, and DLS.

Sample TEMa AFMb DLSc
Dav, nm Dav, nm Hav, nm Deff, nm
cl-micelles 45 ± 3.3 47 ± 6.8 8.7 ± 3.7 90 ± 1.2
a

Number-average diameter (Dav), n = 27. A drop of the sample solution was allowed to settle on a Formvar precoated copper grid and the sample was allowed to air-dry.

b

Number-average height (Hav) and diameter (Dav), n = 55. cl-micelles were deposited from aqueous solutions at pH 6.5 onto APS mica surface and allowed to dry in vacuum.

c

Intensity-average hydrodynamic diameter(Deff) for DLS was determined at pH 7.4, n= 5.

Data are expressed as mean ± SD.