Skip to main content
. 2014 Jun 7;20(21):6608–6614. doi: 10.3748/wjg.v20.i21.6608

Table 4.

Diagnostic performance of positron emission tomography/computerized tomography and computerized tomography in patients with various carcinoembryonic antigen levels

CEA level (ng/mL) CT (%)
PET/CT (%)
Sensitivity Specificity Accuracy Sensitivity Specificity Accuracy
≤ 3.4 (n = 26) 57.1 (8/14) 75 (9/12) 65.4 (17/26) 83.3 (10/12) 85.7 (12/14) 84.6 (22/26)
3.4-10 (n = 29) 78.3 (18/23) 66.7 (4/6) 75.9 (22/29) 96 (24/25) 75 (3/4) 93.1 (27/29)
10-30 (n = 34) 86.7 (26/30) 75 (3/4) 85.3 (29/34) 96.7 (29/30) 75 (3/4) 94.1 (32/34)
> 30 (n = 17) 93.8 (15/16) 100 (1/1) 94.1 (16/17) 100 (16/16) 100 (1/1) 100 (17/17)

PET: Positron emission tomography; CT: Computerized tomography; CRC: Colorectal cancer; CEA: Carcinoembryonic antigen.