Skip to main content
. Author manuscript; available in PMC: 2014 Jun 6.
Published in final edited form as: IEEE Trans Ultrason Ferroelectr Freq Control. 2012 Jul;59(7):1602–1608. doi: 10.1109/TUFFC.2012.2360

Table I.

Simulation parameters for the conventional 1D array and 1.5D ARFI array. With the exception of number of elements and center frequency, all other values were constant between the two designs in order to better compare the improvement in SNRARFI due to increased pushing to tracking beam width ratios.

Conventional 1D 1.5D ARFI
Pushing Tracking Pushing Tracking
Elements 60 96 60 4 × 96
Center Frequency (MHz) 4.21 6.15 2 7
Bandwidth (%) 50 80 50 80
Lateral Pitch (μm) 350
Elevation Pitch (mm) 1