Skip to main content
. 2014 Jun 9;9(6):e99690. doi: 10.1371/journal.pone.0099690

Table 1. Average repeated choroidalsublayer thickness measurements for the central submacular field (CSM) and the total macular field ( µm).

Layer R1 (range) R2 (range) R3 (range) P value Δ R1-R2 (CI, LoA) Δ R1-R3(CI, LoA)
Healthy
Sattler's (CSM) 116±66(10–217) 114±69(10–218) 123±68(6–225) .17 2 (−8–13, 59) −7(−18–5, 64)
Sattler's (total) 98±52(8–196) 94±508–176) 102±58(14–220) .6 2 (−2–8, 32) −4 (−12–2, 39)
Haller's (CSM) 226±80 (89–348) 228±86(87–361) 216±85 (86–382) .54 1(−6–7, 31) −4(−24–16, 66)
Haller's (total) 180±46(79–241) 184±51(78–253) 173±38 (63–228) .2 −4 (−12–4, 45) 9(−13–30, 49)
Eyes with non-neovascular AMD
Sattler's (CSM) 20±4(4–99) 20±4(2–88) 22±4 (5–133) .61 −1 (−0.8–1.4, 17) −1 (−1.5–1, 6)
Sattler's (total) 10±3(2–46) 9±3(2–40) 12±3(4–50) .62 −1 (−0.9–1.4, 6) 0 (0−1, 5)
Haller's (CSM) 139±45 (80–234) 144±33 (82–233) 149±38 (82–219) .37 −3(−14–9, 65) −6 (−14–3, 50)
Haller's (total) 95±27(61–147) 93±27(57–151) 90±21(62–133) .37 2(−3–8, 31) 3 (−5–10, 43)

R1 and R2 represent imaging at the same session. R3 was performed on a different day. P values are stated for the difference between measurements by repeated measures ANOVA. Δ represents the difference. CI is the 95% confidence interval. LoA represents 95% limits of agreement. Data are expressed as the mean ± standard deviation.