Skip to main content
. Author manuscript; available in PMC: 2015 Jul 1.
Published in final edited form as: Comput Med Imaging Graph. 2014 Mar 13;38(5):411–420. doi: 10.1016/j.compmedimag.2014.03.002

Table 2.

False detection, missed detection and total errors resulting from: the proposed change detection method, the SVM method, the SVDD method and the threshold method.

Image 1 from dataset1 (PSNR=30dB) False detection Missed detection Total Errors
Proposed method 0.62 % 4.28 % 0.95 %
SVM 0.97 % 6.47 % 1.68 %
SVDD 1.26 % 7.39 % 2.21 %
Threshold 2.14 % 9.34 % 3.05 %
Image 2 from dataset1 (PSNR=30dB) False detection Missed detection Total Errors
Proposed method 0.68 % 4.01 % 0.81 %
SVM 0.91 % 5.98 % 1.42 %
SVDD 1.68 % 7.35 % 2.38 %
Threshold 2.13 % 9.31 % 3.04 %
Image 3 from dataset1 (PSNR=30dB) False detection Missed detection Total Errors
Proposed method 0.65 % 4.68 % 0.83 %
SVM 0.94 % 6.24 % 1.71 %
SVDD 1.51 % 7.03 % 2.09 %
Threshold 2.10 % 9.43 % 3.17 %
Image 4 from dataset1 (PSNR=30dB) False detection Missed detection Total Errors
Proposed method 0.75 % 4.62 % 1.08 %
SVM 0.96 % 6.98 % 1.73 %
SVDD 1.39 % 7.90 % 2.36 %
Threshold 2.21 % 10.32 % 3.57 %