Table 3.

False detection, missed detection and total errors resulting from: the proposed change detection method, the SVM method and the threshold method using the semi-simulated datasets.

(PSNR=30dB) False detection Missed detection Total Errors
Proposed method 0.58 % 3.81 % 0.86 %
SVM 0.84 % 4.58 % 1.12 %
Threshold 1.51 % 6.58 % 2.03 %
(PSNR=28dB) False detection Missed detection Total Errors
Proposed method 0.62 % 3.85 % 0.88 %
SVM 1.18 % 6.91 % 1.61 %
Threshold 1.98 % 6.92 % 2.71 %
(PSNR=25dB) False detection Missed detection Total Errors
Proposed method 0.75 % 4.61 % 0.97 %
SVM 1.91 % 6.8 % 2.68 %
Threshold 2.32 % 8.17 % 3.18 %
(PSNR=23dB) False detection Missed detection Total Errors
Proposed method 0.91 % 4.77 % 1.20 %
SVM 2.68 % 8.39 % 3.88 %
Threshold 2.73 % 8.63 % 3.97 %