False detection, missed detection and total errors resulting from: the proposed VEM procedure, the MCMC procedure and the ICM procedure using the semi-simulated datasets.

(PSNR=30dB) False detection Missed detection Total Errors
Proposed VEM 0.58 % 3.81 % 0.86 %
MCMC 0.73 % 4.12 % 0.93 %
ICM 0.97 % 5.02 % 1.29 %
(PSNR=28dB) False detection Missed detection Total Errors
Proposed VEM 0.62 % 3.85 % 0.88 %
MCMC 0.83 % 4.32 % 1.02 %
ICM 1.98 % 6.92 % 2.71 %
d(PSNR=25dB) False detection Missed detection Total Errors
Proposed VEM 0.75 % 4.61 % 0.97 %
MCMC 0.85 % 4.46 % 1.04 %
ICM 2.3 % 7.58 % 3.03 %
(PSNR=23dB) False detection Missed detection Total Errors
Proposed VEM 0.91 % 4.77 % 1.20 %
MCMC 0.88 % 4.71 % 1.16 %
ICM 2.69 % 8.61 % 3.82 %