Skip to main content
. 2013 Jul 24;17(4):R154. doi: 10.1186/cc12833

Table 2.

Treatment modalities for low-flow CO 2 removal integrated into the RRT circuit

No.
Double-lumen catheter
Blood flow (ml/min)
Dialysate flow (L/h)
Ultrafiltration (ml/h)
Volume (ml)
Gas flow (L/min)
Oxy FiO 2 (vol. %)
Treatment time (hours)
    t= 4 h t= 24 h t= 4 h t= 24 h t= 4 h t= 24 h t= 24 h      
1
1
250
300
4.0
4.0
100
200
−645
6
1.00
30
2
1
330
400
2.0
2.0
200
0
−705
4
1.00
84
3
1
400
400
2.0
2.0
0
150
605
4
0.50
45
4
1
400
400
2.0
2.0
0
100
1,715
6
0.40
215
5
2
300a
n.a.
2.0 a
n.a.
100 a
n.a.
n.a.
6
0.21
2.5
6
1
500
450
3.0
3.0
0
100
1,340
6
0.21
191
7
1
320
250
2.0
2.0
100
150
−3,345
4
0.21
83
8
2
400
450
2.0
1.5
40
100
−2,055
6
0.21
71
9
1
400
500
2.0
2.0
0
0
180
6
0.21
92
10 1 250 250 2.0 2.0 50 0 2,945 4 0.21 134