Skip to main content
. 2013 Jul 11;17(4):R134. doi: 10.1186/cc12813

Table 5.

Quality criteria for all scores compared.

BIG score TRISS PS09 score
Discrimination

AUROC curve (95% CI) All patients (n = 12206) 0.892 (0.879 - 0.906) 0.922 (0.913 - 0.932) 0.925 (0.915 - 0.934)
AUROC curve (95% CI) Blunt trauma (n = 6540) 0.876 (0.859 - 0.892) 0.917 (0.906 - 0.928) 0.921 (0.911 - 0.932)
AUROC curve (95% CI) Penetrating trauma (n = 5666) 0.920 (0.898 - 0.942) 0.929 (0.912 - 0.947) 0.921 (0.902 - 0.939)

Precision

All patients
Predicted Mortality (%) 4.8 6.6 7.9

Observed Mortality (%; 95% CI) 4.8 (4.4-5.2)
Blunt Trauma
Predicted Mortality (%) 5.5 9.6 11.9

Observed Mortality (%; 95% CI) 6.7 (6.1-7.3)
Penetrating Trauma
Predicted Mortality (%) 4.0 3.2 3.4

Observed Mortality (%; 95% CI) 2.7 (2.3-3.1)

Quality criteria for all scores on all data (n = 12,206), on all blunt (n = 6,540) and penetrating (n = 5,666) trauma patients. Data are presented as AUROC (Area under receiver operating characteristic curve) together with a 95% Confidence Interval (CI).