Table 2. Mean values of SDOCT retinal nerve fiber layer thickness parameters in glaucoma and control eyes with areas under the receiver operating characteristic curves and sensitivities at fixed specificities.

Retinal nerve fiber layer parameters (in microns) Control (mean±SD) Glaucoma (mean±SD) P-value AUC Sensitivity at 95% specificity Sensitivity at 80% specificity
Signal strength index 51±10 47±9 0.003      
Temporal quadrant 79.1±10.6 65.9±14.7 <0.001 0.802 (0.735–0.861) 44.3% (26.3–58.3) 67.0% (55.0–76.8)
Superior quadrant 122.8±18.1 95.2±19.2 <0.001 0.823 (0.746–0.888) 49.1% (25.0–61.9) 79.2% (70.5–90.2)
Nasal quadrant 78.5±12.6 67.2±16.4 <0.001 0.678 (0.583–0.768) 28.3% (16.5–43.0) 48.1% (34.2–63.5)
Inferior quadrant 126.6±19.4 93.6±16.6 <0.001 0.876 (0.819–0.927) 53.8% (33.9–69.6) 81.1% (66.7–91.5)
Average thickness 101.8±11.3 80.5±12.8 <0.001 0.868 (0.801–0.915) 63.2% (42.6–77.2) 78.3% (64.0–86.5)

Abbreviations: AUC, area under the receiver operating characteristic curve; SD, standard deviation; SDOCT, spectral domain optical coherence tomograph.

Figures in brackets are 95% confidence intervals. AUCs and sensitivities are adjusted for the difference in disc area and signal strength index between the control and glaucoma group.