Skip to main content
. Author manuscript; available in PMC: 2015 May 15.
Published in final edited form as: Arch Biochem Biophys. 2014 Apr 5;0:1–11. doi: 10.1016/j.abb.2014.03.013

Table 1.

Numerical results from fitting of the Hill equation (Eq. 1) to Ca2+ titration curves for each pseudo-phosphorylation mutant and control. Parameter standard error is given to the right of each parameter value.

cTnI:cTnT Mutants
(n = 5–10)
Thin filament Thin filament + S1-ADP


pCa50 nH pCa50 nH
  S151CAEDANS:wt 6.27 ± 0.01 0.786 ± 0.014 6.50 ± 0.01 0.765 ± 0.014
S199E 6.29 ± 0.02 0.789 ± 0.019 6.49 ± 0.02 0.744 ± 0.014
T204E 6.09 ± 0.02 0.853 ± 0.01 6.22 ± 0.01 0.716 ± 0.018
S199E/T204E 6.18 ± 0.02 0.731 ± 0.012 6.28 ± 0.02 0.714 ± 0.014
T195E/S199E/T204E 6.36 ± 0.03 0.831 ± 0.017 6.43 ± 0.01 0.741 ± 0.016
T195E/S199E/T204E/T285E 6.47 ± 0.03 0.711 ± 0.019 6.53 ± 0.02 0.683 ± 0.022
  S167CAEDANS:wt 6.11 ± 0.02 1.03 ± 0.03 6.28 ± 0.01 0.773 ± 0.017
S199E 6.03 ± 0.01 0.881 ± 0.024 6.26 ± 0.02 0.826 ± 0.018
T204E 5.98 ± 0.02 1.14 ± 0.04 6.12 ± 0.01 0.843 ± 0.016
S199E/T204E 6.11 ± 0.01 1.13 ± 0.04 6.31 ± 0.02 0.705 ± 0.018
T195E/S199E/T204E 6.17 ± 0.01 1.11 ± 0.03 6.28 ± 0.01 0.759 ± 0.017
T195E/S199E/T204E/T285E 6.21 ± 0.01 0.924 ± 0.013 6.29 ± 0.02 0.863 ± 0.019