Table 2.

Prediction results for SEM/confocal images. Prediction is based on the proposed IA and standard IA methods, and we use sum of squared prediction residuals (SSR) to evaluate the prediction results. The p-value is computed using a paired t-test.

Method mean std p-value
Proposed IA 1.52 ×105 5.79 ×104 0.0002
Standard IA 2.83 ×105 7.11 ×104