Skip to main content
. 2014 May 16;14(5):8686–8704. doi: 10.3390/s140508686

Table 2.

Segmentation accuracy of crack (C) and open joint (OJ) segmentations by CBHO.

Image ID Accuracy Index (%)

Compl Corr Quality

C OJ C OJ C OJ
(a) 27.48 6.89 9.56 3.14 7.63 2.21
(b) 56.89 0.51 21.89 0.43 18.77 0.23
(c) 71.39 0.12 39.35 0.18 33.99 0.07
(d) 70.18 0.11 11.51 0.03 10.97 0.03
(e) 82.79 0.00 8.94 0.00 8.78 0.00
(f) 53.43 2.65 22.21 4.58 18.61 1.71
(g) 52.16 2.35 6.21 4.46 5.87 1.57
(h) 65.86 2.25 9.75 2.30 9.28 1.15
(i) 79.65 10.66 11.72 2.45 11.37 2.03
(j) 4.94 1.16 0.73 0.36 0.64 0.28
Average 62.20 2.67 15.68 1.79 13.92 0.93
Standard Deviation 16.96 3.48 10.50 1.83 8.77 0.90

p.s. The extreme values of Image (j) of crack are excluded in calculation of average and standard deviation.