Skip to main content
. Author manuscript; available in PMC: 2014 Jun 23.
Published in final edited form as: Int J Audiol. 2014 Mar;53(0 2):S76–S83. doi: 10.3109/14992027.2013.857438

Table 4.

Noise exposures at SC level within facility

N SCs
TWA noise levels
Measurements >85 dBA
Baseline
(1992-1994)
Final (2009-
2011)
Δ Baseline-final
Baseline (1992-
1994)
Final (2009-
2011)
Δ Baseline-final
Location Baseline
(1992-
1994)
Final
(2009-
2011)
N* Mean
(dBA)
N* Mean
(dBA)
dBA/yr
**
p-value N* N (%) >85
dBA
N* N (%)
>85 dBA
> 85 dBA
(% per yr)
**
p-
value
1 19 23 411 81.6 237 80.6 −0.11 0.01 19 2 (10.5) 23 3 (13.0) −0.14 0.79
2 10 13 146 87.1 247 85.9 −0.18 0.26 10 7 (70.0) 13 9 (69.2) −1.41 0.22
3 14 14 370 83.8 193 84.4 0.04 0.59 14 4 (28.6) 14 7 (50.0) 1.58 0.03
4 13 23 108 84.4 540 81.2 −0.14 0.35 13 5 (38.5) 23 1 (4.4) −2.18 0.08
5 20 15 209 85.1 161 79.5 −0.31 0.0003 20 11 (55.0) 15 1 (6.7) −2.95 0.0001
6 7 8 108 86.9 77 74.5 −0.84 0.002 7 4 (57.1) 8 0 (0) −3.21 0.01
7 11 19 96 86.7 171 79.6 −0.45 0.00 11 7 (63.6) 19 1 (5.3) −2.65 0.0005
8 8 8 93 83.7 61 76.9 −0.53 0.01 8 2 (25.0) 8 0 (0) −2.13 0.02
*

Required at least 3 measurements to be included

**

Weighted by number of SCs in the year