Table 5.

Treatment planning, immobilization, and image guidance in SABR for central lung tumors.

Reference Respiratory motion management ITV FDG PET for target definition Dose calculation/TPS Technique Immobilization Image guidance
Haasbeek et al. (30) e Y −/BrainLab 3D ExacTrac system
Nuyttens et al. (31) RTT −/CyberKnife IMRT Fiducial marker tracking per CyberKnife system
Rowe et al. (32) e Y AAA/− 3D, IMRT Full length vacuum cushion CBCT
Oshiro et al. (33) c −/Eclipse (Varian) 3D Individualized body casts Gated KV-radiographs
Unger et al. (34) RTT Non-isocentric inverse planning algorithm with heterogeneity correction/CyberKnife IMRT IR emitting external markers and internal fiducial markers used for real time tumor tracking with CyberKnife
Milano et al. (35) d Y Y −/BrainLab Arcs ExacTrac system
Chang et al. (36) e Y −/− 3D CT-on-rail with orthogonal radiographs to confirm isocenter
Fakiris et al. (14) a Y −/− 3D SBF with abdominal compression Daily treatment guided by external markers on SBF
Onimaru et al. (17) b Y 3D RTP with heterogeneity correction 3D No immobilization cradles Orthogonal radiographs on the first day
Song et al. (18) ,c,da,c,d Y −/Render 3D system (Elekta) or Eclipse (Varian) Vacuum fitted SBF CBCT
Stauder et al. (19) e Y Y −/Eclipse (Varian) 3D BodyFix vacuum system CBCT
Peulen et al. (20) a Y Pencil beam algorithm with heterogeneity correction/− 3D SBF with abdominal compression CT prior to each treatment
Bral et al. (21) ,cb,c Y Y −/BrainLab 3D Low density cradle with IR skin markers on the thorax ExacTrac-like system using both external and internal markers
Xia et al. (22) f Y   N1 LN delineation Body gamma knife planning system MLC based gamma knife Vacuum bag from head to pelvis
Guckenberger et al. (23) e Y Collapsed cone algorithm/− 3D SBF or BodyFix systems CT, in-room CT, then CBCT since 2005
Baba et al. (24) b Y ? AAA/eclipse (Varian) 3D BodyFix system
Olsen et al. (25) e Y Superposition convolution algorithm with heterogeneity correction/− 3D SBF system or alpha cradle CBCT
Andratschke et al. (26) f Y Unknown algorithm with heterogeneity correction/− 3D/arcs Vacuum couch and low pressure foil CT prior to each treatment, then CBCT since 2008
Takeda et al. (27) f Y Superposition algorithm with heterogeneity correction/XiO (CMS) DCMAT Corset
Stephans et al. (28) b Y Unknown with heterogeneity correction/BrainLab IMRT BodyFix system ExacTrac system
Janssen et al. (29) e Y −/− SBF with abdominal compression CBCT

aForced shallow breathing with abdominal compression.

bInhalation and exhalation breath hold CTs used to generate ITV.

cRespiratory gating.

dBreath hold/active breathing control

e4D CT.

fSlow CT.

SBF, stereotactic body frame; DCMAT, dynamic conformal multiple arc therapy; RTT, real time tracking; Y, yes; ITV refers to that generated with motion encompassing technique or that accounted for when generating the PTV; –, unknown.