. 2014 May-Jun;22(3):194–203. doi: 10.1590/1678-775720130528

Table 1.

Mean and standard deviations of the static friction during sliding tests. Comparison between different types of ligation and duration of intraoral bracket use

Type of ligation   Force (N)    
  New 12 months 24 months P value *
Metallic ligatures 2/4 2.64±0.43 1.72±0.35 1.91±0.47 n.s. 3 /p<0.05 1,2
Metallic ligatures 4/4 1.98±0.26 1.95±0.26 2.42±0.36 n.s. 1,2,3
Elastomeric 4.31±0.27 3.70±0.29 4.18±0.59 n.s. 2,3 /p<0.05 1
Slide® 2.74±0.35 1.67±0.19 1.51±0.16 n.s. 3/p<0.05 1,2
P value * n.s. 6 n.s. 4,6,8 n.s. 6  
  p<0.05 4,5,7,8,9 p<0.05 5,7,9 p<0.05 4,5,7,8,9  
*

P values were obtained by two way analysis of variance (one way ANOVA) followed by the Bonferroni's post hoc test

n.s.=not significant (p>0.05)

1

New versus 12 months

2

New versus 24 months

3

12 months versus 24 months

4

2/4 versus 4/4

5

2/4 versus Elastomeric

6

2/4 versus Slide®

7

4/4 versus Elastomeric

8

4/4 versus Slide®

9

Elastomeric versus Slide®