Table 3.

Effective radiation toe dose (mSv) results for four radiologists monitored during a sample of procedures performed within a 7-week period in our institution

Radiologist Left foot (mSv)
Right foot (mSv)
No. of procedures monitored No. of annual procedures Estimated annual toe dose (mSv)
Fifth toe Third toe Hallux Hallux Third toe Fifth toe
1 3.0 3.2 3.6 4.9 4.1 3.7 9 199 110
2 9.3 9.9 9.4 6.0 5.5 4.8 22 157 70
3 3.8 4.0 4.4 7.2 7.6 8.9 14 167 110
4 0.5 0.6 0.5 0.4 0.3 0.3 20 137 <10

The thermoluminescent dosemeter (TLD) positions are approximated to the nearest toe. The estimated annual dose is based on the highest TLD result and the number of procedures performed by the corresponding radiologist over the preceding calendar year.