Table 3. Formate and methanol kinetics in the patients treated on CVVHD12, 13, 14, 15, 16, 17, 18, 19 and CVVHDF20, 21, 22, 23, 24.

Patient Methanol t ½, h R2 methanol Formate t ½, h R2 formate Observation time during CVVHD/HDF, h Blood FR, ml/min Dialysate FR, ml/h Substitution fluid FR, ml/h Dialyzer type Dialyzer surface area, m2 Anticoagulation Dialysate temperature Number of data points Complications Number of circuits Frequency of circuit blotting Ultrafiltration, ml/h
12 11.7 0.99 5.9 0.92 34.0 100 2000 - Aquarius 1.2 Citrate 36.5 8 0 1 0 -
13 9.8 0.99 4.5 1.00 32.0 130 2400 - Multifiltrate Fresenius 1.8 Citrate 38.0 4 0 1 0 -
14 7.7 0.94 5.9 0.88 32.0 130 2500 - Multifiltrate Fresenius 1.8 Citrate 36.5 6 0 1 0 -
15 6.8 0.99 4.1 1.00 32.5 100 2500 - Aquarius 1.9 Citrate 36.5 6 0 1 0 -
16 9.0 0.99 2.4 0.97 26.5 250 2500 - Multifiltrate Fresenius 1.8 Hep 39.0 5 0 1 0 -
17 5.6 0.95 2.1 0.96 26.0 150 3000 - Multifiltrate Fresenius 1.8 Citrate 36.5 6 0 1 0 -
18 5.8 0.99 2.4 1.00 28.5 200 4800 - Multifiltrate Fresenius 1.8 Citrate 38.0 4 0 1 0 -
19 5.3 0.96 1.9 1.00 31.5 200 4800 - Multifiltrate Fresenius 1.8 Citrate 38.0 4 0 1 0 -
20 10.6 0.99 4.0 0.97 34.5 120 1000 1200 Aquarius 1.2 Hep 36.5 7 BL 1 0 100
21 8.4 0.95 6.2 0.98 29.5 200 1000 1200 Multifiltrate Fresenius 1.4 Hep 38.0 7 0 1 0 100 (24 h), 50 (5.5 h)
22 10.0 0.99 3.2 0.83 36.0 150 1800 600 Multifiltrate Fresenius 1.8 Citrate 35.0 9 0 1 0 100
23 6.3 0.98 2.1 1.00 35.5 150 1800 600 Aquarius 1.9 Hep 36.5 8 0 1 1 150
24 8.1 0.98 1.9 0.85 37.5 150 2000 600 Multifiltrate Fresenius 1.8 Citrate 35.0 8 0 1 0 150
Mean 8.1 0.98 3.6 0.95 32.0 155 2470     1.75              
LCL95% 6.9   2.6   29.8 128 1750     1.65              
UCL95% 9.3   4.6   34.2 183 3180     1.84              

Abbreviations: BL, bleeding during HD; CI 95%, 95% confidence interval; CVVHD/HDF, continuous veno-venous hemodialysis/hemodiafiltration; FR, flow rate; LCL, the lower limit of a confidence interval at the 95% level; UCL, the upper limit of a confidence interval at the 95% level. Polysulfone dialyzer membranes have been used in all cases.