Table 2.
Bioreactor | DO (%) | NaHCO3 addition | Xmax–H (106cell/mL) | Xmax–S (106cell/mL) | μmax (day−1) | Reference time (day) | (pg/cell) | (pg/cell) | (pg/cell) | (pg/cell) | (pg/cell) | (mol/mol) | (mol/mol) | (mol/mol) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Bioflo 110 | 10 | Without | 1.85 | 1.73 | 1.30 | 1.78EEP | 197 | 1317 | 10 | 14 | 1094 | 0.05 | 0.59 | 1.68 |
2.23MCC | 238 | 1287 | 14 | 34 | 1049 | 0.06 | 1.17 | 1.65 | ||||||
30 | Without | 3.63 | 2.95 | 1.93 | 2.23EEP | 139 | 655 | 12 | 14 | 536 | 0.09 | 0.85 | 1.65 | |
2.82MCC | 130 | 696 | 11 | 13 | 565 | 0.09 | 0.84 | 1.64 | ||||||
With | 4.94 | 3.94 | 1.52 | 2.24EEP | 102 | 533 | 3 | 8 | 378 | 0.03 | 0.60 | 1.44 | ||
2.78MCC | 93 | 681 | 3 | 9 | 440 | 0.03 | 0.78 | 1.31 | ||||||
50 | Without | 4.34 | 3.73 | 1.55 | 2.16EEP | 147 | 539 | 7 | 8 | 372 | 0.05 | 0.42 | 1.40 | |
2.83MCC | 115 | 581 | 7 | 8 | 368 | 0.06 | 0.58 | 1.28 | ||||||
With | 4.24 | 3.68 | 1.68 | 2.30EEP | 141 | 654 | 6 | 4 | 559 | 0.05 | 0.25 | 1.73 | ||
2.88MCC | 116 | 988 | 7 | 6 | 752 | 0.06 | 0.44 | 1.54 | ||||||
Celligen | 10 | Without | 4.59 | 3.51 | 1.81 | 1.98EEP | 111 | 692 | 7 | 0.2 | 492 | 0.06 | 0.01 | 1.44 |
2.95MCC | 100 | 864 | 6 | 5.0 | 604 | 0.06 | 0.04 | 1.42 | ||||||
30 | Without | 3.07 | 2.97 | 1.69 | 2.10EEP | 181 | 1045 | 27 | 5.5 | 919 | 0.15 | 0.25 | 1.78 | |
2.80MCC | 146 | 1059 | 19 | 4.4 | 914 | 0.13 | 0.25 | 1.75 | ||||||
50 | Without | 3.16 | 3.35 | 1.49 | 2.01EEP | 204 | 1090 | 22 | 22 | 902 | 0.11 | 0.88 | 1.67 | |
2.67MCC | 223 | 1619 | 25 | 26 | 1335 | 0.11 | 0.94 | 1.67 |
All factors were calculated using as initial moment, the time when the first sample of batch experiments was taken. Reference times, end of exponential phase (EEP) and maximum cell concentration (MCM), were used to define the end of time interval to calculate factors. Gln, Glc, Glu, NH4 and Lac represent glutamine, glucose, glutamate, ammonium and lactate, respectively. Xmax–H and Xmax–S represent maximum viable cell concentration determined by hemocytometer and total cell concentration by Millipore® Scepter handheld automated cell counter, respectively